Short Term - AIRLESSCO SL1100 Operation And Repair Manual

Airless 3000 psi (20.7mpa, 207 bar) maximum working pressure
Table of Contents

Advertisement

Operation
Shutdown
1. Relieve Pressure, page 7.
2. Clean the tip and gun as recommended in the sepa-
rate Gun Manual supplied with the gun.
3. If spraying water-based material or a material that
could harden in the sprayer overnight, flush the
sprayer after use. See Flushing, page 8.
10
Storage

Short Term

1. Flush sprayer with compatible solvent before stor-
ing, then fill the pump and hoses with an oil based
solvent such as mineral spirits or Graco or Airlessco
Pump Armor.
For oil base paint: flush with mineral spirits
For water-base paint: flush with water, then min-
eral spirits and leave the pump, hose and gun
filled with mineral spirits.
Long Term
For longer storage, use Graco or Airlessco Pump Armor.
Shut off sprayer, Relieve Pressure, page 7, and make
sure prime valve is left open.
Start Up After Storage
Before using water-base paint, flush sprayer with soapy
water and then a clean water flush. When using oil-base
paint, flush out the mineral spirits with the material to be
sprayed.
NOTE: Always store unit indoors.