Carton Inventory; Additional Items Needed For Installation; Operator Dimensions And Specifications - Chamberlain LA400 Installation And Operation Manual

Medium duty swing gate operator
Hide thumbs Also See for LA400:
Table of Contents

Advertisement

Carton Inventory

HARDWARE KIT
DESCRIPTION
Post Bracket
Pull to Open Bracket
Hex Bolt 5/16"-18 X 1-1/2"
Square Neck Carriage Bolt 3/8"-16 X 6"
Hex Nut 3/8"-16
Hex Nut 5/16"-18
Flat Washer 5/16"
Flat Washer 3/8"
Lock Washer 5/16"
Lock Washer 3/8"
Gate Mounting Bracket
Hairpin Clip
Pin
Hex Bolt 3/8"-16 X 1-1/2"
Bolt 2-3/4"
NOTE: Carton inventory is based on a Single Operator. For Primary (Gate 1) and Secondary (Gate 2) installation the carton
inventory is doubled except for control box.

Additional Items Needed for Installation

Power Wire: 120Vac (Stranded Copper Wire)
Wire Gauge
16
10

Operator Dimensions and Specifications

Weight: 13.2 lbs. (6 kg.)
4.00"
(10.2 cm)
4.50"
.250"
(11.2 cm)
(0.635 cm)
QTY
Permanent fasteners for warning sign
Earth Ground Rod (Optional)
Length
100' (30 m)
1000' (305 m)
14"
(35.6 cm)
10"
6"
(25.4 cm)
(15.2 cm)
36.3"
(92.1 cm)
.475" DIA.
(1.2 cm DIA.)
37.4"
(95.0 cm)
CONTROL BOX LA400 - CONT
DESCRIPTION
1
Control Box
1
Hardware Bag
5
MISCELLANEOUS
2
Linear Actuator Arm
2
Motor Cable - Six Conductor
5
Warning Sign
5
Battery
5
Plug-In Transformer
5
5
LA400-S (SECOND LINEAR ACTUATOR ARM)
1
Extension Cable - Six Conductor
4
Junction Box - IP56
2
Phillips Head Mounting Screws
1
Anchors
2
Terminal Block - Twelve Connectors
Power Wire: 24Vac Transformer (Stranded Copper Wire)
Wire Gauge
OR
14
12
Operating Cycles
Main Supply (Motor)
Current Consumption
Power Consumption
Battery Charger Supply
Solar Panel Supply (Optional)
Maximum Gate Width
Maximum Gate Weight
Protection Class
Travel Speed
Rated Operating Time
Temperature
Main Supply (Control) Dedicated Circuit
Absorbed Power
Protection Fuse Battery
3
40' (12.2 m)
Length
500' (152 m)
1000' (305 m)
26Vac, 29VA or 36Vdc, 40VA
See Accessories
16 ft. (4.9 m)
550 Lbs. (249.5 kg)
14-18 seconds for a 90 degree opening
-20˚C to + 50˚C
-4˚F to + 122˚F
120V~/60Hz
QTY
1
1
9' (2.7 m)
2
2
1
1
4
4
1
100 per day
24Vdc
2A
48 Watts
NEMA 3R
4 Minutes
0.75 Watts
ATC 20A

Hide quick links: