Installing Pellet Inserts into Factory Built or Masonry Fireplaces
Means must be provided for removal of the insert to clean the chimney liner.
Inserts that project in front of the fireplace must be supplied with appropriate supporting means.
A permanent metal warning label must be attached to the back of the fireplace stating that the
fireplace must be restored to its original condition for safe use without the insert.
This sticker is supplied in the "Owners Manual" and accessories packaging, found in the unit.
(See the following statement)
THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE A FIREPLACE
INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON PRIOR TO
RE-USE AS A CONVENTIONAL FIREPLACE!
When installing into a masonry chimney, it is recommended that the exhaust vent be extended to
the top of the chimney as shown in figure 26.
However, if the vent pipe does not extend to the top of the chimney, the pipe must extend a
minimum of 18" above the damper.
You must seal the damper area with a steel plate when using the direct connection method.
FULL CHIMNEY RELINE
Note: This installation
6"
PelPro Appliances
F
I
F
I
IREPLACE
NSERT
IREPLACE
NSERT
is
recommended
for all chimney installations!
8"
www.pelprostoves.com
I
I
NSTALLATION
NSTALLATION
DIRECT CONNECTION
Note: This installation
8"
6"
. . . cont
not
allowed in Canada