Camera unit Composite Cable ~ RCPS1 connections

Connections for the Camera unit Composite cable should be made to the terminals
as follows:
URM70 Video:
Connect the centre core to the terminal marked "VIDEO"
Connect the screen to the terminal marked "GND"
Power:
Connect the Red 20AWG cable to the terminal marked PTZ 1P
Connect the Black 20AWG cable to the terminal marked PTZ 1N
Washer:
Connect one White 20AWG cable to the upper terminal marked AUX1
Connect the other White 20AWG cable to the upper terminal marked AUX2
RS485 data:
Connect the Yellow 26AWG cable to the upper terminal marked DATA 5
Connect the Blue 26AWG cable to the upper terminal marked DATA 6
Earth:
Connect the Green/Yellow cable to the Earth stud adjacent to the BNC
output socket.
The IR Lamp and Ethernet terminals are reserved for future use.
ON
F0
SLOT
P1
CHOKE
LL1
7446720047
AC IN
1P
24V AC IN

RCPS1 System Side Connections

Video:
The Video output from the RCPS1 and Camera unit is available on the pcb
mounted BNC socket. Connect the coaxial cable back to the monitor / matrix
or DVR to this socket. If the Camera unit and control system are configured to
use coax based telemetry, it will pass through this connector.
Data:
Connect RS485A (RS485+) to the lower terminal marked DATA 5
Connect RS485B (RS485-) to the lower terminal marked DATA 6
Power:
Connect 240VAC Live the to the mains input marked L
Connect 240VAC Neutral the to the mains input marked N
Connect 240VAC Earth the to the mains input marked E
F2
F1
P3
P2
L0
1P
L1
2P
L2
R3
R4
CN0
1N
2P
2N
WASHER
PTZ
PUMP
Figure 4
AUX
POWER
DATA
2
3
4
5
6
7
1
7
3
6
1
2
4
5
DATA ETHERNET
AUX
POWER
7
V
ETHERNET
D
8 9 10
E
O
CE- RCPS1 1.0
VIDEO OUT
9 10
8