Startup - Graco Ultra 395 Operation Manual

Electric airless sprayers
Hide thumbs Also See for Ultra 395:
Table of Contents

Advertisement

ti2719a
9
Turn prime valve down.
-
1
Turn pressure control to
lowest pressure.
309665L
10 Place siphon tube set in grounded metal pail partially filled with flushing fluid. Attach ground
wire to pail and to true earth ground. Do 1. - 5. of Startup, page 9 to flush out storage oil
shipped in sprayer. Use water to flush water-base paint and mineral spirits to flush oil-base
paint and storage oil.

Startup

ti2706a
2
Turn power ON.
WASTE
ti2756B
FLUSH
-
3
Increase pressure to start
motor and allow fluid
to circulate through drain
tube for 15 seconds; then
turn pressure down.
Startup
ti2712a
4
Turn prime valve
horizontal.Take spray gun
trigger safety OFF.
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents