ti2707a
1
Turn power OFF and
unplug sprayer
WASTE
5
Remove siphon tube set from
paint and place in flushing
fluid. Use water for water
base paint and mineral spirits
for oil base paint.
ti2719a
9
Turn prime valve down and
allow flushing fluid to
circulate for 1 to 2 minutes
to clean drain tube.
12
Cleanup
-
ti2599a
ti2614a
WASTE
WASTE
2
Turn pressure to lowest
setting. Trigger gun to
relieve pressure.
ti2810a
ti2712a
ti2707a
6
Plug in sprayer. Turn power
ON. Turn prime valve
horizontal.
PAINT
ti2820a
FLUSH
ti2707a
10
Raise siphon tube above
flushing fluid and run sprayer
for 15 to 30 seconds to drain
fluid. Turn power OFF
WASTE
RESÍDUOS
À JETER
DESECHO
ti2595a
3
Put drain tube in pail.
Turn prime valve down.
ti2770a
PAINT
ti2817a
7
Hold gun against paint pail.
Take trigger safety OFF.
Trigger gun and increase
pressure until flushing fluid
appears
ti2712a
WASTE
11
Close drain valve. Trigger
gun into flushing pail to purge
fluid from hose.
ti2719a
ti2769a
4
Remove guard and
SwitchTip.
ti2599a
WASTE
WASTE
8
Move gun to flushing pail,
hold gun against pail, trigger
gun to thoroughly flush
system. Release trigger and
put trigger safety ON.
ti2713a
12
Open prime valve.
Cleanup
ti2719a
309665L