9. Remove compressor
Twist off the three foot nuts
on compressor and then
remove the compressor.
10. Remove condenser sub-assy
1
Remove the screws con-
necting the support (con-
denser) and condenser
assy,and then remove the
support (condenser).
2
Remove the chassis sub-
assy and condenser sub-
assy.
Procedure
support
chassis sub-assy
compressor
condenser sub-assy