4.Remove the axial flow fan
1
Remove the nuts fixing the
blade and thenremove the
axial flow fan.
2
R e m o v e t h e 4 t a p p i n g
screws fixing the motor;
disconnect the leading wire
insert of the motor and
then remove the motor.Re-
move the 2 tapping screws
fixing the motor support
and then pull the motor
support upwards to remove
it.
5.Remove Electric Box Assy
Remove the screws fixing
the electric box sub-assy;
loosen the wire bundle; pull
out the wiring terminals and
then pull the electric box
upwards to remove it.
Procedure
Axial Flow Fan
fan motor xing frame
fi
fan motor
Electric Box
Points
The screw has reverse
winding.