Alarm Displaying; Aeg Version; Other Versions; Examples Of Alarm Display - Electrolux EWM1000 Service Manual

Front loader washer
Hide thumbs Also See for EWM1000:
Table of Contents

Advertisement

ENV06 EWM11xx EWM21xx EWM25xx/35xx

3.4 Alarm displaying

3.4.1

AEG Version:

The alarm is displayed by a repeated flashing sequence of the LED placed above
the button START / PAUSE with yellow and red light (0,5 seconds on, 0,5
seconds off with a 2,5 second pause between the sequences).
LED indicator START / PAUSE with yellow light → indicates the first digit of
the alarm code (family).
LED indicator START / PAUS with red light → indicates the second digit of
the alarm code (internal number of the family).
These two LEDs are featured in all models.
3.4.2

Other versions:

The alarm is displayed by a repeated flashing sequence of the START / PAUSE
button with red and green light (0,5 seconds on, 0,5 seconds off with a 2,5
second pause between the sequences).
LED indicator START / PAUSE with red light → indicates the first digit of the
alarm code (family)
LED indicator START / PAUSE with green light → indicates the second digit
of the alarm code (internal number of the family)
These two LEDs are featured in all models.
Notes:
The first letter of the alarm code "E" (Error) is not displayed, since this letter is common to all alarm
codes.
The alarm code "families" are shown in hexadecimal; in other words:
→ A is represented by 10 flashes
→ B is represented by 11 flashes
→ ...
→ F is represented by 15 flashes
Configuration errors are shown by the flashing of all the LEDs, placed inside or above the button
START/PAUSE.
3.4.3

Examples of alarm display

Example: Alarm E43 (problems with the door interlock Triac) will display the following:
the sequence of four flashes of the START / PAUSE button with red light (version AEG LED yellow
light), indicates the first number E
the sequence of three flashes of the START / PAUSE button with green light (version AEG LED red
light), indicates the second number E4
Button/LED - START / PAUSE
red/yellow light
On/Off
ON/OFF
(Ver. AEG)
3.4.4

Operation of alarms during diagnostics

All alarms are enabled during the components diagnostic phase.
QUICK GUIDE AND APPLIANCES LIST
4
3;
3
;
Time
Value
ON/OFF
(Sec.)
0.5
1
0.5
0.5
2
0.5
0.5
3
0.5
0.5
4
0.5
1.5
Pause
45/176
Button/LED - START / PAUSE
red/green light
On/Off
Time
(Ver. AEG)
(Sec.)
0.5
0.5
0.5
0.5
0.5
0.5
2.5
Value
1
2
3
Pause
599 72 40-80