7.2.1
Displaying the alarm
The alarm is displayed by a repeated flashing sequence of the START / PAUSE
button with red and green light (0,5 seconds on, 0,5 seconds off with a 2,5 second
pause between the sequences).
•
button indicator START / PAUSE with red light → indicates the first digit of the
alarm code (family)
•
button indicator START / PAUSE with green light → indicates the second digit of
the alarm code (internal number of the family)
These two LEDs are featured in all models.
Notes:
•
The first letter of the alarm code "E" (Error) is not displayed, since this letter is common to all alarm codes.
•
The alarm code "families" are shown in hexadecimal; in other words:
→ A is represented by 10 flashes
→ B is represented by 11 flashes
→ ...
→ F is represented by 15 flashes
•
Configuration errors are shown by the flashing of all the LEDs (user interface not configured).
7.2.2
Examples of alarm display
Example: Alarm E43 (problems with the door interlock Triac) will display the following:
•
the sequence of four flashes of the START / PAUSE button with red light, indicates the first number E
•
the sequence of three flashes of the START / PAUSE button with green light, indicates the second number
3
E4
;
START / PAUSE button with red
ON / OFF
7.2.3
Operation of alarms during diagnostics
All alarms are enabled during the components diagnostics phase.
SOI/DT 2007-02 dmm
light
ON /
Time (Sec.)
OFF
0.5
1
0.5
0.5
2
0.5
0.5
3
0.5
0.5
4
0.5
1.5
Pause
23/56
START / PAUSE button with green
light
Time (Sec.)
ON / OFF
0.5
0.5
0.5
0.5
0.5
0.5
2.5
4
3;
Time
(Sec.)
1
2
3
Pause
599 38 60-23