The station cabling for the G1E should be a home run from the jack to the telephone room. The
termination should be at conventional 66 type connecting blocks or Krone blocks or directly to the
provided station connectors. One pair twisted wiring is required for each station location. The G1E
station ports are not digital twin ports and each station must be a home run to either the inner or outer
pair of each DDK connector. Attention to proper cabling will go a long way towards a successful
installation and minimizing service calls after installation. Some guidelines for running station cable are
as follows:
Avoid running cable parallel to fluorescent light fixtures or electrical lines not in conduit. If these
obstacles are unavoidable, run the cable at right angles across them.
Do not run station cable inside conduit already occupied by electrical wiring.
Do not run station cable near equipment with electric motors or strong magnetic fields.
Do not place station cable on the ground where it can be stepped on or rolled over by office
furniture or office equipment.