Town & Country Fireplaces TCVT.FMPV3 Installation And Operating Instructions Manual

Low noise horizontal flush mount power vent kit

Advertisement

Quick Links

IMPORTANT:
THESE INSTRUCTIONS ARE TO REMAIN
WITH THE HOMEOWNER
These instructions are supplementary to the Installation
and Operating Instructions supplied with the fi replace
and should be kept together. Refer to the Installation
and Operating Instructions for proper gas supply, safety
requirements and operating instructions.
111011-16
LOW NOISE
HORIZONTAL FLUSH
MOUNT POWER
VENT KIT
(FOR MAXIMUM 6' HORIZONTAL RUNS)
Flush Mount Power
Vent Assy.
For use with
any TC Series
"C" unit,
except TC54.
TCVT.FMPV3
INSTALLATION AND
OPERATING
INSTRUCTIONS
TCVT.FMPV3
Wall Sleeve
Assembly
Inner Wall Plate
Wall Pipe Cover
Vent Adaptor
5056.4265C3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TCVT.FMPV3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Town & Country Fireplaces TCVT.FMPV3

  • Page 1: Operating Instructions

    VENT KIT (FOR MAXIMUM 6’ HORIZONTAL RUNS) Flush Mount Power Vent Assy. Wall Sleeve Assembly Inner Wall Plate Wall Pipe Cover For use with Vent Adaptor any TC Series “C” unit, except TC54. TCVT.FMPV3 INSTALLATION AND OPERATING INSTRUCTIONS 111011-16 TCVT.FMPV3 5056.4265C3...
  • Page 2: Power Vent Installation

    For every 90-degree elbow MAX. 6’ Min. venting - 3 ft plus after the fi rst transition, one 90-degree elbow subtract 2’ from max. horizontal run. Min. 1 1/2” Clearance to 66’ MAX. VERTICAL combustible surfaces from vent pipe. 111011-16 TCVT.FMPV3...
  • Page 3: Minimum Vent Length Chart

    ** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the fl oor* * as specifi ed in CGA B149 Installation Codes, Note: local Codes or Regulation may require different clearances * for U.S.A. Installations follow the current National Fuel Gas Code, ANSI Z223.1 111011-16 TCVT.FMPV3...
  • Page 4: Horizontal (Side Wall) Venting

    As per local building codes. See Fig. #6. 6. For wall thicknesses 7 1/2” or less, install the inner wall plate supplied over the terminal as shown in Fig. #6 and secure to the framing. See Fig. #7. 111011-16 TCVT.FMPV3...
  • Page 5 Fig #1 and Fig #2. Fig. #7 INNER WALL PLATE 14 3/4” 7 7/8” SEAL WITH SILICONE ON ALL FOUR SIDES 14 1/2” NOTCH AT THE TOP Fig. #6 TERMINAL SECURING FLANGE WALL FINISH NO DEEPER THAN 1 1/4” EXHAUST 111011-16 TCVT.FMPV3...
  • Page 6 WALL THICKNESS GREATER THAN INNER WALL PLATE 7 1/2” UP TO MAX. 16 1/2” INNER WALL PLATE WALL SLEEVE WALL PIPE COVER ASSEMBLY ATTACH SCREWS FROM THE INSIDE WALL SLEEVE ASSEMBLY Fig. #11 WALL PIPE COVER NOTCH AT TOP 111011-16 TCVT.FMPV3...
  • Page 7: Control System Connection

    (Also see wiring diagram on Pg.13) SPADE CONNECTORS IN BLACK WIRE LOOP Fig. #14 ORANGE WIRE FROM MODULE TO VALVE HOT WIRE FROM BLOWER Fig. #15 SUPPLIED WIRES TO CONNECT TO BLACK WIRE ON MODULE HOT WIRE FROM 120V SUPPLY 111011-16 TCVT.FMPV3...
  • Page 8: Pressure Switch Installation

    This is not a fault indicator. HIGH SIDE OF SWITCH WARNING: This switch must be installed in a vertical position and will not function if installed otherwise. (Fig. 16) LOW SIDE OF SWITCH Fig. #18a Fig. #18 111011-16 TCVT.FMPV3...
  • Page 9 This is not a fault indicator. HIGH SIDE OF SWITCH WARNING: This switch must be installed in a vertical position and will not function if installed otherwise (Fig.21). LOW SIDE OF SWITCH Fig. #22 Fig. #21 111011-16 TCVT.FMPV3...
  • Page 10: Fan Wiring

    Place the end cover back onto the upper tabs and secure in place with 2 screws on top and 2 on bottom. Fig. #23 SCREWS Fig. #26 GROUND SCREW DECORATIVE COVER CONNECTOR BLOCK Fig. #24 Fig. #27 GROUND SCREW MAIN POWER CONNECTIONS SCREWS 111011-16 TCVT.FMPV3...
  • Page 11 NOTE:For all other units use the restrictor NOTE: If this powervent is to be installed in a TC30 shown in Fig. #29. then it should use the full restrictor as shown in Fig. #28. Fig. #29 Fig. #28 111011-16 TCVT.FMPV3...
  • Page 12: Venting Components

    Cathedral ceiling support box (blk) TM-OS Offset Support 1605500 Firestop spacer TM-SR Roof Support 1605460B Wall thimble (blk) TM-WS Adjustable Wall Support 1605430 Wall support band TM-5WT Insulated Wall Thimble TM-5TR Trim Ring, Black TM-5AS Attic Radiation Shield / Firestop 111011-16 TCVT.FMPV3...
  • Page 13: Wiring Diagram

    Wiring Diagram 111011-16 TCVT.FMPV3...
  • Page 14: Replacement Parts

    INNER WALL PLATE 5096.816 VENTING ADAPTER TCVT.9280 PRESSURE SWITCH ASSEMBLY TCVT.507156C POWER VENT SWITCH WIRE 5068.8065 1/4” LDF PAPER GASKET TCVT.8035 TCVT.FMPV OUTER CASING ASSEMBLY 5024.63 BLOWER, POWERVENT TCVT.80285WLD WALL SLEEVE ASSEMBLY 8029 WALL PIPE COVER * NOT SHOWN 111011-16 TCVT.FMPV3...
  • Page 15 111011-16 TCVT.FMPV3...
  • Page 16 TECHNICAL SUPPORT: (250) 748-1184 www.townandcountryfi replaces.net 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada...