VENT KIT (FOR MAXIMUM 6’ HORIZONTAL RUNS) Flush Mount Power Vent Assy. Wall Sleeve Assembly Inner Wall Plate Wall Pipe Cover For use with Vent Adaptor any TC Series “C” unit, except TC54. TCVT.FMPV3 INSTALLATION AND OPERATING INSTRUCTIONS 111011-16 TCVT.FMPV3 5056.4265C3...
For every 90-degree elbow MAX. 6’ Min. venting - 3 ft plus after the fi rst transition, one 90-degree elbow subtract 2’ from max. horizontal run. Min. 1 1/2” Clearance to 66’ MAX. VERTICAL combustible surfaces from vent pipe. 111011-16 TCVT.FMPV3...
** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the fl oor* * as specifi ed in CGA B149 Installation Codes, Note: local Codes or Regulation may require different clearances * for U.S.A. Installations follow the current National Fuel Gas Code, ANSI Z223.1 111011-16 TCVT.FMPV3...
As per local building codes. See Fig. #6. 6. For wall thicknesses 7 1/2” or less, install the inner wall plate supplied over the terminal as shown in Fig. #6 and secure to the framing. See Fig. #7. 111011-16 TCVT.FMPV3...
Page 5
Fig #1 and Fig #2. Fig. #7 INNER WALL PLATE 14 3/4” 7 7/8” SEAL WITH SILICONE ON ALL FOUR SIDES 14 1/2” NOTCH AT THE TOP Fig. #6 TERMINAL SECURING FLANGE WALL FINISH NO DEEPER THAN 1 1/4” EXHAUST 111011-16 TCVT.FMPV3...
Page 6
WALL THICKNESS GREATER THAN INNER WALL PLATE 7 1/2” UP TO MAX. 16 1/2” INNER WALL PLATE WALL SLEEVE WALL PIPE COVER ASSEMBLY ATTACH SCREWS FROM THE INSIDE WALL SLEEVE ASSEMBLY Fig. #11 WALL PIPE COVER NOTCH AT TOP 111011-16 TCVT.FMPV3...
(Also see wiring diagram on Pg.13) SPADE CONNECTORS IN BLACK WIRE LOOP Fig. #14 ORANGE WIRE FROM MODULE TO VALVE HOT WIRE FROM BLOWER Fig. #15 SUPPLIED WIRES TO CONNECT TO BLACK WIRE ON MODULE HOT WIRE FROM 120V SUPPLY 111011-16 TCVT.FMPV3...
This is not a fault indicator. HIGH SIDE OF SWITCH WARNING: This switch must be installed in a vertical position and will not function if installed otherwise. (Fig. 16) LOW SIDE OF SWITCH Fig. #18a Fig. #18 111011-16 TCVT.FMPV3...
Page 9
This is not a fault indicator. HIGH SIDE OF SWITCH WARNING: This switch must be installed in a vertical position and will not function if installed otherwise (Fig.21). LOW SIDE OF SWITCH Fig. #22 Fig. #21 111011-16 TCVT.FMPV3...
Place the end cover back onto the upper tabs and secure in place with 2 screws on top and 2 on bottom. Fig. #23 SCREWS Fig. #26 GROUND SCREW DECORATIVE COVER CONNECTOR BLOCK Fig. #24 Fig. #27 GROUND SCREW MAIN POWER CONNECTIONS SCREWS 111011-16 TCVT.FMPV3...
Page 11
NOTE:For all other units use the restrictor NOTE: If this powervent is to be installed in a TC30 shown in Fig. #29. then it should use the full restrictor as shown in Fig. #28. Fig. #29 Fig. #28 111011-16 TCVT.FMPV3...
Need help?
Do you have a question about the TCVT.FMPV3 and is the answer not in the manual?
Questions and answers