Connecting Your LTM-4x4HDSDI 4x4 HD-SDI / SDI Router
6.1 Dipswitch Settings
By default, all dipswitches are set to OFF.
Figure 3 illustrates the LTM-4x4HDSDI dipswitches:
6.1.1
Setting the Machine # Dipswitches
The Machine # determines the position of a LTM-4x4HDSDI unit,
specifying which LTM-4x4HDSDI unit is being controlled when several
LTM-4x4HDSDI units connect to a PC or serial controller. Set the Machine
# on a LTM-4x4HDSDI unit via SETUP DIPS 1, 2, 3 and 4, according to
Table 3.
When using a standalone LTM-4x4HDSDI unit, set the Machine # to 1.
When connecting more than one LTM-4x4HDSDI unit, set the first machine
(the Master) that is closest to the PC, as Machine # 1 (dipswitches are set to
OFF).
8
SETUP
ON
Figure 3: LTM-4x4HDSDI SETUP Dipswitches
Table 3: Machine # Dipswitch Settings
Mach. #
DIP 1
1
OFF
2
OFF
3
OFF
4
OFF
5
OFF
6
OFF
7
OFF
8
OFF
1 2 3 4
DIP 2
DIP 3
DIP 4
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON