Safety Label - Regency L390E Owner's Manual

Gas insert
Hide thumbs Also See for L390E:
Table of Contents

Advertisement

SAFETY LABEL

This is a copy of the labels that accompany each L390E Gas Insert. We
have printed a copy of the contents here for your review.
4001172
Minimum Clearances to Combustibles
from Insert
Side wall
Ceiling
Mantel
Min. Alcove Width
Max. Alcove Depth
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel
Gas Code ou CSA-B149.1 en vigueur.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si un kit certifié est utilisé.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements.
AVERTISSEMENT : Ce foyer a été converti pour utilisation avec un foyer au gaz encastrable et ne peut être utiliser pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remplacées et que le foyer ait été approuvé de nouveau par l'autorité compétente.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only.
For use only with barrier (Part # 397-929) Follow installation instructions.
Electrical supply / Électrique 115VAC, 2.5 A, 60Hz, Less than 10A
VENTED GAS FIREPLACE HEATER -
GAZ À ÉVACUATION -
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas appliance is installed.
6
VENTED GAS FIREPLACE HEATER
Listed:
/
FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour: CANADA and U.S.A.
é
CAN/CGA-2.17-M91(R2009)
Tested to:
ANSI Z21.88a-2012
Conforms to:
CSA 2.33a-2012
Certified to:
NATURAL GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
5"
Low Setting Man. pressure
1.6"
Max. Manifold pressure
3.5"
Orifice size
#35
Minimum input
22,000
Maximum input
31,000
PROPANE GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
11"
Low Setting Man. pressure
6.4"
Max. Manifold pressure
10"
Orifice size
#53
Minimum input
26,000
Maximum input
31,000
A
6"
(152mm)
B
60"
(1524mm)
C
24"
(610mm)
K
54"
(1372mm)
L
36"
(914mm)
Regency Fireplace Products,
Delta BC, CANADA
NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
NOTE: Regency units are constantly being improved. Check the
label on the unit and if there is a difference, the label on the unit is
the correct one.
398
Duplicate Serial number
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ETIQUETTE
398
Serial No. / No de serie
MODEL HZI390E-NG2
É
QUIP A L'UISINE POUR GAZ NATURAL
É
MODEL HZI390E- NG2
WC
(1.25 kpa)
Pression d'allimentation minimum
WC
(0.41 kpa)
Pression la tubulure d' chappement basse
à
WC
(0.87 kpa)
Pression la tubulure d' chappement lev e
à
DMS
Dimensions de l'orifice
Btu/h
(6.45
kW
)
D bit Calorifique minimum
é
Btu/h
(9.09 kW)
D bit Calorifique maximum
é
MODEL HZI390E-LP2
É
QUIP A L'UISINE POUR GAZ PROPANE
É
MODEL HZI390E- LP2
WC
(2.73 kpa)
Pression d'allimentation minimum
WC
(1.59 kpa)
Pression la tubulure d' chappement basse
à
WC
(2.48 kpa)
Pression la tubulure d' chappement lev e
à
DMS
Dimensions de l'orifice
Btu/h (7.62 kW)
D bit Calorifique minimum
é
Btu/h (9.09 kW)
D bit Calorifique maximum
é
Mantel Clearances
Min. Hearth Width
Min. Hearth Length
A
A
Max. Mantle Depth
G
G
.
C
C
L
L
B
B
D
D
E
E
K
K
MADE IN CANADA /FABRIQUE AU CANADA
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil.
Pour l'utilisation seulement avec la Partie de barrière No. (397-929)
Suivez les instructions d'installation.
Fan Part # 911-071
é
é
é
é
é
é
é
é
D
14"
(356mm)
E
40"
(1016mm)
G
12"
(305mm)
FOYER AU
919-235a
L390E-2 / HZI390E-2 Direct Vent Gas Insert

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hzi390e

Table of Contents