Fan Maintenance - With Gtmf Remote Control; For L390Eb Or Hzi390Eb - Regency L390E Owner's Manual

Gas insert
Hide thumbs Also See for L390E:
Table of Contents

Advertisement

MAINTENANCE

FAN MAINTENANCE - WITH GTMF REMOTE CONTROL

Note: To access the side and rear access panels both the gas and venting
will need to be disconnected(see vent/fl ue installation in this manual)
for proper removal.
There is no access to the blower from the front of this appliance.
Before you begin:
Shut off the gas supply to the unit.
Disconnect all electrical supply to the unit.
Always let the appliance cool to room temperature before servicing.
1. Remove 7 screws and loosen 4 screws along the bottom to remove fan
access panel -see Diagram 1a
Remove 4 screws to remove side access panel - see Diagram 1b
= Remove
= Loosen
2. Disconnect the fan wire harness through the rear panel. Disconnect 2 x
1/4" spade connectors to the fan terminals. Disconnect the ground lug to
the fan using the screw provided.
Strain Relief
Power Cord
Fan Controller
Wire Retainer
Fan Wire Harness
46

FOR L390EB OR HZI390EB

Diagram 1b
Diagram 1a
Fan Terminals
Ground Wire
Fan Mounting Bracket
Diagram 2
3. Remove fan and fan access panel from unit
4. Remove fan from back access panel by removing 3 screws from the
outside of fan access panel.
5. To install - reverse steps.
Electrical Grounding Instructions
This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug.