AFi RR-985D-SL Instruction Manual

Eight channel video receiver with two channels of multi-protocol data and remote diagnostic interface

Advertisement

Quick Links

Instruction Manual
RR-985D-SL
Eight Channel Video Receiver
With Two Channels of Multi-Protocol Data
And Remote Diagnostic Interface
© Copyright 2007, American Fibertek, Inc. 0531JD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RR-985D-SL and is the answer not in the manual?

Questions and answers

Summary of Contents for AFi RR-985D-SL

  • Page 1 Instruction Manual RR-985D-SL Eight Channel Video Receiver With Two Channels of Multi-Protocol Data And Remote Diagnostic Interface © Copyright 2007, American Fibertek, Inc. 0531JD...
  • Page 2: Table Of Contents

    Table of Contents Functional Description ................3 Installation...................4 Power Source ..................4 Power Connection................4 Fiber Connections ................5 Video Input Connections ..............5 Data Input / Output Connections............6 Data Configuration Switches...............7 Data Termination And Bias Switches..........7 RR-980D-1510 Status LED Indicators ..........9 RR-482D-1470/1490 Status LED Indicators ........9 Warranty And Service Information ............8...
  • Page 3: Functional Description

    FUNCTIONAL DESCRIPTION The RR-985D-SL operates as half of a receiver / receiver pair for the transmission of eight channels of high performance 10 bit digital NTSC, PAL, RS170, or RS343 video signals. The RR-985D-SL also supports combinations of up to two bi-directional RS422, RS232, or RS485 data channels or two Manchester data channels.
  • Page 4: Installation

    INSTALLATION THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES. The individual rack cards slide into any five slots in the SR-20D subrack. The recommended configuration is shown below. Use a small screwdriver to push and lock the ¼ turn fasteners into place.
  • Page 5: Fiber Connections

    FIBER CONNECTIONS The RR-985D-SL consists of a RR-980D-1510 and a RR-482D-1470/1490 that transmit at different wavelengths. The RR-980D-1510 has one optical port on the back of the unit and the RR-482D-1470/1490 has two optical ports on the back of the unit. A short patch cord (supplied) connects each of these three SC fiber ports to the correspondingly labeled fiber port on the RR- CWDM-4 fiber multiplexer.
  • Page 6: Data Input / Output Connections

    RR-985D-SL. The plus terminal of the copper device is connected to the plus terminal of the RR-985D-SL and the minus is connected to the minus. The reverse flow of data from the RR- 985D-SL to the copper device follows the same pattern. Not all manufactures follow standard EIA terminology.
  • Page 7: Data Configuration Switches

    DATA CONFIGURATION SWITCHES NOTE: This unit is shipped with Data Channel 1 and Data Channel 2 in the RS485 4-wire configuration. For other configurations of data channel 1 or data channel 2, please refer to the drawing below for changes to the default switch settings. These configuration switches are located at the bottom of the RR-482D-1470/1490 unit and can be modified without opening the unit.
  • Page 8: Warranty And Service Information

    Please remember when using offset bias switches that they must be used in pairs. If switch # 1 is on then switch # 3 must also be on. The same situation applies for switch # 4 and switch # 6. Also, if using offset bias, it is important that the corresponding termination resistor switch be in the on position.
  • Page 9: Rr-980D-1510 Status Led Indicators

    RR-980D-1510 STATUS INDICATORS The RR-980D-1510 receiver provides the following front panel LED status indicators to aid in installation and troubleshooting: VIDEO 1 THROUGH VIDEO 8 A bi-color LED indicator is provided for each of the eight video channel outputs. DC power and video status associated with each of these LEDs are summarized below.
  • Page 10 RR-482D-1470/1490 STATUS INDICATORS The RR-482D-1470/1490 receiver provides the following front panel LED status indicators to aid in installation and troubleshooting: DATA TX / RX INDICATORS DATA TX and DATA RX indicators are provided to monitor each of the two available data channels.
  • Page 11 DATA TX A green LED indicator is provided to monitor the data coming in from the electrical interface, through the RR-482D-1470/1490, and out onto the fiber. The intensity of this indicator will vary with input data patterns, however in typical applications it will cycle on and off as data is transmitted.
  • Page 12 LIFETIME WARRANTY INFORMATION American Fibertek, Inc warrants that at the time of delivery the products delivered will be free of defects in materials and workmanship. Defective products will be repaired or replaced at the exclusive option of American Fibertek. A Return Material Authorization (RMA) number is required to send the products back in case of return.