Outside
Faucet
(Hard
Water)
Soft, Cold Water
Soft, Hot Water
Remote
Location
Installation
_
Sump
I-F
Airgap
H
I-1/Z'
Standpipe
Airgap
1!4" RED Tubing
Outside
Faucet
(Hard
Water)
Line
GREEN
T_lbing to Reverse
Osmosis
System
Sediment
Filter
S0ft, C01d
Water Heater
Water Softener
""
Tubinc
to
Airgap
/
%¢
(
Laundry Tub
Airgap
1-1/2"
Floor
Drain
Figure 10
Main
Shutoff
Valve
Reverse
Osmosis
System
YELLOW Tubing
to-lankStorage
I
Storage
Tank
Water Meter
BLUE Tubing
to Reverse
Osmosis
Air
Gap Faucet
Figure 9
INSTALL A REMOTE
DRAIN
POINT
AND AIR GAP
(Remote
Location)
You can also run the drain tubing to an existing drain in
the house. A floor drain, laundry
tub, standpipe,
sump,
etc. are suitable
drain points. See Figure
10. This type of
drain is the preferred
over the p- trap drain adapter.
Check your local codes. Longer lengths of tubing (see
parts list in back of manual)
may be needed.
Always be sure to provide
an air gap between
the end of
the hose and the drain point. This will prevent
water
from backing up into the system. Airgaps
are required
code in most areas.
To install
a remote
drain point, complete
the following
steps:
1. Locate the 1/4" red tubing on the Reverse Osmosis
fil-
ter assembly. See Figure 9.
2. Determine
if this length is long enough
to reach the
drain point.
3. if not, disconnect
the 1/4" red tubing
and replace with
an adequate
length of tubing to reach the drain point.
Refer to Step 6 later in the manual
on how to discon-
nect and connect tubing.
NOTE: A flow control
insert is located
in the red
tube, Refer to Key No. 14 on Page 26, This insert
must be saved and placed
in the new length
of tub-
4. Run the tubing to the drain point and secure at the
end with a bracket
(purchased
locally). See Figure 10.
Provide
a 1-1/2" air gap between
the end of the tube
and the drain. See Figure 10.
Questions?
Call The Kenmore
Water Line 1-800-426-9345
or visit KenmoreWater.com
10