Imperx bobcat hd-sdi User Manual page 134

Intelligent, high-resolution, field upgradeable, programmable, digital cameras
Hide thumbs Also See for bobcat hd-sdi:
Table of Contents

Advertisement

Standard Strobe: Controls the strobe position and pulse duration for Strobe 1
Trigger Strobe: Sets the duration and delay of a strobe sync pulse (with
5.7.8.
Color Window
This window sets Brightness, Contrast, Saturation, Hue, and Offset for the
primary RGB colors by using a Color Correction Matrix (CCM). In addition
the color window provides different White Balance modes including Auto
White Balance with tracking and displays the calculated white balance
coefficients – Figure 5.17. The Color Window is disabled for the Mono
cameras.
Imperx, Inc.
6421 Congress Ave.
Boca Raton, FL 33487
+1 (561) 989-0006
a strobe pulse associated with rising edge of the trigger
pulse.
and Strobe 2. The user can set the individual strobe position
relative to the beginning of the frame, via the slider or by
entering the desired value. The strobe pulse duration can be
set for each strobe individually. The user can set the strobe
position and duration within the camera frame period with 1
us resolution.
respect to the trigger pulse) sent to the camera output. The
user can set the strobe duration and the delay from 0 to
16777215 us.
Figure 5.17 – Color Window.
134 of 175
BOBCAT HD-SDI
Hardware User's Manual
Rev. 1.4
6/2/2014

Advertisement