IBM 21Y Maintenance Manual page 144

Type 8657
Table of Contents

Advertisement

Error
Code/Symptom
035-XXX-S99
(Failed RAID test
on PCI slot S. S =
number of failing
PCI slot. Check
System Error Log
before replacing a
FRU.)
035-XXX-SNN
(Check System
Error Log before
replacing a FRU.
S = number of
failing PCI slot; NN
= SCSI ID of failing
fixed disk.)
035-253-S99
(RAID adapter
initialization failure)
075-XXX-000
(Failed Power
Supply test)
089-XXX-001
(Failed
Microprocessor
test)
089-XXX-002
(Failed Optional
Microprocessor
test)
180-XXX-003
(Failed System
Board LED test)
201-XXX-0NN
(Failed Memory
test, see "Memory
Settings" on page
36.) NN = DIMM
location.
201-XXX-999
(Multiple DIMM
failure, see error
text.)
FRU/Action
1. Adapter
2. SCSI Backplane
3. Cable
1. Fixed Disk with SCSI ID NN
on RAID adapter in PCI slot
S.
1. ServeRAID Adapter in slot S
is not configured properly.
Obtain the basic and extended
configuration status and refer
to the ServeRAID Hardware
Maintenance Manual for more
information.
2. Cable
3. Adapter
1. Power Supply
1. Microprocessor
1. Optional Microprocessor 2
1. System Board
1. DIMM Location J1-J4
2. Memory card
1. See error text for failing
DIMMs
2. Memory card
Symptom-to-FRU index
135

Advertisement

Table of Contents
loading