Safety Information; Ac And/Or Dc Power Safety Warning (Ac And/Or Dc Powered Units) - Intel ZT 8101 10/100 User Manual

Table of Contents

Advertisement

Caution: System Airflow Requirements. Platform components such as single board
computers, Ethernet switches, etc., are designed to operate with external air flow.
Components can be destroyed if they are operated without external air flow. External air flow is
normally provided by chassis fans when components are installed in compatible chassis.
Filler panels must be installed over unused chassis slots so that airflow requirements are met.
Refer to the product data sheet for airflow requirements if you are installing components in
custom chassis.
Warning: Microprocessor Heatsinks May Become Hot During Normal Operation. To avoid
burns, do not allow anything to touch processor heatsinks.
Caution: Do Not Operate Without Covers. To avoid electric shock or fire hazard, do not operate
this product with any removed enclosure covers or panels.
Caution: Do Not Operate in an Explosive Atmosphere. To avoid injury, fire hazard, or
explosion, do not operate this product in an explosive atmosphere.
Caution: If Your System Has Multiple Power Supply Sources. Disconnect all external power
connections before servicing.
Warning: Power Supplies Must Be Replaced by Qualified Service Personnel Only.
Caution: Lithium batteries are not field-replacable units. There is a danger of explosion if a
battery is incorrectly replaced or handled. Do not disassemble or recharge the battery. Do not
dispose of the battery in fire. When the battery is replaced, the same type or an equivalent type
recommended by the manufacturer must be used. Used batteries must be disposed of according
to the manufacturer's instructions. Return the unit to Intel for battery service.

Safety Information

AC and/or DC Power Safety Warning (AC and/or DC Powered Units)

The AC and/or DC Power cord is your unit's main AC and/or DC disconnecting device, and
must be easily accessible at all times. Auxiliary AC and/or DC On/Off switches and/or circuit
breaker switches are for power control functions only (NOT THE MAIN DISCONNECT).
For your safety, use only a power cord with a grounded plug. The enclosure is also provided with a
separate Earth ground connection/stud. The Earth ground connection should be installed prior to the
application of power or peripheral connections and should never be disconnected while power or
peripheral connections exist.
Intel® NetStructure™ ZT 8101 10/100 Ethernet Switch User's Manual
Agency Approvals
135