Intel Express 10 User Manual
Intel Express 10 User Manual

Intel Express 10 User Manual

Intel express 10/100 fast ethernet switch

Advertisement

Quick Links

Intel Express 10/100
Fast Ethernet Switch
User Guide
Part No. 663096-001

Advertisement

Table of Contents
loading

Summary of Contents for Intel Express 10

  • Page 1 Intel Express 10/100 Fast Ethernet Switch User Guide Part No. 663096-001...
  • Page 2 Copyright © 1996, Intel Corporation. All rights reserved. Intel Corporation, 5200 NE Elam Young Parkway, Hillsboro, OR 97124-6497 Intel Corporation assumes no responsibility for errors or omissions in this manual. Nor does Intel make any commitment to update the information contained herein.
  • Page 3: Table Of Contents

    Contents Quick Start Chapter 1 Hardware Installation and Network Topology Overview ............................3 Installation and Setup ........................4 Using the Switch ..........................5 Port status LEDs ........................5 Management status LEDs ......................6 Cabling Requirements ........................7 UTP requirements ........................7 Fiber optic requirements ......................
  • Page 4 C O N T E N T S Intel Express 10/100 Fast Ethernet Switch SNMP Commands .......................... 48 SNMP community strings ......................48 SNMP trap message commands ....................49 Switching Database Commands ...................... 50 Database control commands ..................... 51 Custom filtering ........................54 VLAN Commands ..........................
  • Page 5: Quick Start

    Quick Start 1. Install the Express 10/100 Switch in a rack or on a shelf or table and plug the cord in. If you’re in Europe or Asia, or any other country that has a 220-volt electrical system, set the power supply switch to 230 (115 is the default).
  • Page 6 8. Download the Intel MIB (Management Information Base) file from an Intel online service and compile it into your NMS. The MIB filename is SWCH2MIB.EXE. You can find the file on Intel’s Customer Support web site (http://support.intel.com) or the Intel BBS (Host: ftp.intel.com, Directory: pub/support/ enduser_reseller).
  • Page 7: Chapter 1 Hardware Installation And Network Topology

    Network Topology Overview The Intel Express 10/100 Fast Ethernet Switch features eight auto- negotiating 10BASE-T/100BASE-TX ports. Each port supports an Ethernet (10 Mbps) or Fast Ethernet (100 Mbps) segment. The switch also has two slots for optional two-port media adapters (such as 100BASE-TX or 100BASE-FX).
  • Page 8: Installation And Setup

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch Installation and Setup Install the switch in a rack or on a shelf. For rack placement, connect the switch to a 19-inch rack using the enclosed rack mount brackets.
  • Page 9: Using The Switch

    C H A P T E R Hardware Installation and Network Topology Using the Switch The switch requires minimal user intervention. It automatically learns the addresses of new devices as you connect them, and will relearn addresses dynamically if you reconfigure the network. It also automatically detects the speed of connected devices.
  • Page 10: Management Status Leds

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch Flow Flow control. Lights whenever too much traffic is entering on a port. When this happens, the switch’s buffers fill and it’s forced to back pressure the traffic out to the segment for retransmission.
  • Page 11: Cabling Requirements

    (repeater), router or bridge. See page 12 for an example. Fiber optic requirements The optional 100BASE-FX fiber optic media adapter (Intel product code ES101MAFX) lets you use multimode fiber optic cable to connect two switches, or to connect the switch to a hub, bridge, or router.
  • Page 12: Straight-Through Vs. Crossover Cables

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch Straight-through vs. crossover cables Ports on the switch are wired MDI-X so you can use a straight- through cable when connecting to a workstation or server (adapter cards are wired MDI).
  • Page 13 Different switch and repeater manufacturers implement their port configurations differently. The following guidelines are based on the Express 10/100 Switch, the Intel Express 100BASE-TX Stackable Hub (repeater) and the EtherExpress™ family of adapters (server or workstation). These apply to the majority of switches and hubs and all...
  • Page 14: Typical Configurations

    100 Mbps workgroup environment In the mixed 10 and 100 Mbps environment, workgroup clients should be connected to a hubs such as the Intel Express 10/100BASE-TX Stackable Hub. All hub stacks should be connected to the Express 10/100 Switch. Servers or busy workstations should also be connected directly to the 10/100 Switch.
  • Page 15 C H A P T E R Hardware Installation and Network Topology Configuration guidelines: Servers or workstations: Configure servers or workstations directly connected to the switch for full duplex. Since the traffic is two-way traffic, you’ll see a performance increase with a full duplex configuration.
  • Page 16: Configuring The Wide Area Network (Wan) Or Multi-Floor Environment

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch Configuring the Wide Area Network (WAN) or multi-floor environment Connections to the backbone are most effective using fiber optic cabling, especially when devices are separated by multiple floors or buildings.
  • Page 17 412 meters. Two-port 100BASE-TX expansion are also available (Intel order code ES101MATX). Full duplex and flow control between Express 10/100 switches: The only time you can configure full duplex and flow control simultaneously is between two Express 10/100 switches. Special information is added to packets between switches to accomplish this.
  • Page 18: Repeater Count Limitations

    100BASE-TX There can be one class 1 repeater/hub between the switch and any workstation or server (a stack of Intel Express 100BASE-TX Hubs counts as a single hub). Also, the total diameter of a segment can’t exceed 200 meters when using UTP cable. That is, the distance between any two nodes on a segment (or the switch and a node on the other side of a hub) can’t exceed 200 meters.
  • Page 19: Configuring And Managing The Switch

    Use SNMP-compliant management software such as Intel LANDesk Network Manager (not included). • Use the Express 10/100 Switch’s internal Console Manager either by directly connecting a serial cable or through Telnet. To use SNMP management software or Telnet to the switch, you must first connect to the switch using a serial cable and use the Console Manager to assign an IP address.
  • Page 20: Accessing The Console Manager

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch NOTE Accessing the Console For more information about any of the commands used in Manager this chapter, see Chapter 3, Console Command Refer- ence. The Console Manager software is contained in the switch’s nonvolatile RAM (NVRAM).
  • Page 21: Using The Console Manager

    C H A P T E R Configuring and Managing the Switch Using the Console Manager The Console Manager provides an out-of-band (not on the network) connection to the switch. Use the Console Manager to • assign an IP configuration to the switch. •...
  • Page 22 C H A P T E R Intel Express 10/100 Fast Ethernet Switch Some commands have parameters that determine how settings are saved and when they’re implemented. Some are changed in • the running configuration so that the new value is used immediately (the option).
  • Page 23: Console Manager Command Groups

    C H A P T E R Configuring and Managing the Switch Console Manager command groups The Console Manager has several categories of commands: • Console commands: help, banner, login/logout, console parameters setup. • System commands: system status, reset commands, download commands, and system debug commands.
  • Page 24: Sample Console Manager Session

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch Sample Console Manager Session Refer to the diagram below when reading the sample configuration procedures on pages 21 through 29. Procedures using this diagram • Configuring the SNMP agent for IP (page 21) •...
  • Page 25: Configuring The Snmp Agent For Ip

    For more information on the command, see page 46. ping Download the MIB from Intel’s Customer Support World Wide Web site (http://support.intel.com). The file is compressed in the file SWCH2MIB.EXE. Compile the MIB into your NMS. See your NMS documentation for more information.
  • Page 26: Configuring A Port For Full Duplex

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch NOTE Configuring a port for full duplex You must have a point-to- point connection to establish Configuring a port for full duplex allows the switch to send and a full-duplex connection receive packets simultaneously with the destination device.
  • Page 27: Creating Virtual Lans (Vlans)

    C H A P T E R Configuring and Managing the Switch Creating Virtual LANs (VLANs) You can create two types of VLANs: • Security VLANs (SVLANs). Ports in an SVLAN can exchange frames only with other ports in the same SVLAN. SVLANs are used for security to prevent access to devices on the network.
  • Page 28 C H A P T E R Intel Express 10/100 Fast Ethernet Switch Create the two SVLANs. Type the commands: set-sec-vlan all 3-5-7 set-sec-vlan all 1-2-3-4-6-7-8 These commands create two SVLANs and saves the entries in NVRAM. Replace with to save the entry without...
  • Page 29: Monitoring Traffic

    C H A P T E R Configuring and Managing the Switch Monitoring traffic Use monitoring commands to determine the traffic volume from specific ports or between ports. This information helps you determine the network’s traffic patterns so you can adjust your network topology for maximum efficiency.
  • Page 30 C H A P T E R Intel Express 10/100 Fast Ethernet Switch To check traffic on a port Determine the port you want to check. Type the command. For example: SYS_console> get-br-cnt 3 Ethernet Switching Counters for port 3...
  • Page 31: Interpreting Statistics

    Is there a duplex mismatch with the switch? If a switch port is set to full duplex and connected to a node set to half duplex, or vice versa, you could see problems. Hubs such as the Intel Express Stackable hub can only be half duplex.
  • Page 32 C H A P T E R Intel Express 10/100 Fast Ethernet Switch Statistic Definitions Transmit OK: The number of valid frames sent from the port. Underflow Errors: Internal error. A normal ratio of this counter to the Transmit OK counter is 1% or less.
  • Page 33 C H A P T E R Configuring and Managing the Switch etherStatsMcastPkts: The number of frames that are detected without errors and are directed to a non-broadcast group address. This doesn’t include frames received with Too Long, Runt, FCS, or Alignment errors.
  • Page 34: Chapter 3 Console Command Reference

    Console Command Reference Type at the Console Manager prompt to display the list of available command groups and a short explanation of each. Type the name of a group to display commands relevant to that group. SYS_console> ? Commands groups are: --------------------------------------------------- console Console related commands...
  • Page 35: Console Command-Line Summary

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch Console Command-line Summary Console Commands help-kbd Lists the help and shortcut keys. banner Displays the Console Manager logo. clear Clears the screen. login Exits Console Manager and displays the login screen.
  • Page 36 C H A P T E R Console Command Reference set-sw-file <filename> Sets the SNMP agent software filename for download. get-rsw-file Displays the SNMP agent software remote filename. set-rsw-file <filename> Sets the SNMP agent software remote filename for download. get-tftp-srvr Displays the IP address of the TFTP server.
  • Page 37 C H A P T E R Intel Express 10/100 Fast Ethernet Switch set-slip-conf <IPaddress> <netmask> <broadcast> Sets the SLIP configuration. get-gatew Displays the default gateway. set-gatew <IPaddress> Sets the default gateway. get-arp-tbl Displays the Address Resolution Protocol (ARP) table.
  • Page 38 C H A P T E R Console Command Reference Switching Database Commands get-lt-entry <index> Displays a switching database entry. get-lt-16 {<index>|*> Displays 16 switching database entries starting at a given item number. find-lt-addr <mac_address> Searches for an address in the switching database. del-lt-entry <index>...
  • Page 39 C H A P T E R Intel Express 10/100 Fast Ethernet Switch get-svlan-tbl {run|nvram} Displays the SVLAN table. set-mon-port <port> Sets the monitoring port. monitor <port> Starts port monitoring. stop-mon Stops port monitoring. get-lt-filter <mac_address> Displays the filter for a given MAC address.
  • Page 40 C H A P T E R Console Command Reference Port Configuration Commands get-port-cfg Displays the configuration of all the ports. set-port-dplex <port-number> {half|full} Sets a port’s duplex mode to half or full. set-speed-sel <port-number> {asense|10|100} Sets a port’s speed to 10, 100, or auto detect. set-port-fctrl <port-number>...
  • Page 41: Console Commands

    Displays the Express 10/100 Switch Console Manager logo. clear Clears the screen and displays the command prompt. login Exits the Console Manager, but doesn’t disconnect a Telnet session.
  • Page 42: System Commands

    Displays general status information about the switch and its SNMP agent hardware and software: SYS_console>sys-stat Intel Express 10/100 Fast Ethernet Switch SNMP Agent Software - Version <version> SNMP Object ID is : < .1.3.6.1.4.1.629.1.1.3 > System MAC Address :...
  • Page 43 C H A P T E R Intel Express 10/100 Fast Ethernet Switch The screen displays the following information: • SNMP agent software version and release date. • Device SNMP object ID. • Device MAC address. • System uptime (in 1/100 of a second) and in days, hours, minutes, and seconds.
  • Page 44 C H A P T E R Console Command Reference init-nvram Resets the NVRAM on the SNMP agent to the default values. The changes don’t take effect until you use the warm-reset cold-reset commands or cycle the power. Appendix A lists the default values. set-line-slip set-line-slip {9600|19200|38400} Changes the console serial port to SLIP mode for out-of-band SNMP...
  • Page 45 C H A P T E R Intel Express 10/100 Fast Ethernet Switch set-rsw-file set-rsw-file <filename> Sets the name of the SNMP agent software remote file for download. This is the file downloaded from a TFTP server, if you’ve defined one.
  • Page 46: Ip Commands

    C H A P T E R Console Command Reference start-fg start-fg <dport-bitmask> <count> <rate> Starts frame generation. is a hex bitmask of the ports dport-bitmask to generate traffic on. For example, a of 3E sends dport-bitmask frames to ports 2, 3, 4, 5, 6. The specifies the number of frames count to send on each port.
  • Page 47 C H A P T E R Intel Express 10/100 Fast Ethernet Switch set-ip set-ip <IPaddress> Sets the IP address of the switch (technically, the switch’s SNMP agent). If no IP address was previously set (default configuration), the new value is saved in NVRAM and used immediately. Otherwise, the...
  • Page 48 C H A P T E R Console Command Reference get-slip-conf Displays the current SLIP configuration. set-slip set-slip <IPaddress> Sets the SLIP address, which can’t be the same as the IP address. set-slip-conf set-slip-conf <IPaddress> <netmask> <broadcast> Sets the SLIP configuration. The arguments are the same as set-ip-conf get-gatew Displays the default gateway.
  • Page 49: Ping Commands

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch Ping Commands command sends an Internet Control Message Protocol ping (ICMP) echo request packet to a station. The ping process is asynchronous, so any responses are mixed in with other system console messages.
  • Page 50: Address Resolution Protocol (Arp) Commands

    C H A P T E R Console Command Reference Address Resolution Protocol (ARP) Commands get-arp-tbl Displays the ARP table. The table lists the port and MAC address for each IP address the switch has communicated with recently. SYS_console> get-arp-tbl IfIndex IpAddress MAC Address...
  • Page 51: Snmp Commands

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch SNMP Commands Use these commands to configure the SNMP agent itself — access and trap configuration. SNMP community strings SNMP community strings authenticate access to the Management Information Base (MIB).
  • Page 52: Snmp Trap Message Commands

    SNMP authentication failure due to an incorrect community string, or similar event. The SNMP trap commands let you specify • whether the Express 10/100 Switch issues an authentication trap. • which NMSs (up to five) the SNMP agent sends traps to. get-auth Displays the authentication trap setting.
  • Page 53: Switching Database Commands

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch add-trap add-trap <IPaddress> <trap-community> Enters the IP address of the receiving station and the trap community string that appears in the trap message. The trap table can contain up to five receiving stations.
  • Page 54: Database Control Commands

    C H A P T E R Console Command Reference Self (not user configurable). If on (denoted as a +), the entry is a system address. These are the switch’s individual and group addresses, as well as other addresses added by the management system.
  • Page 55 C H A P T E R Intel Express 10/100 Fast Ethernet Switch get-lt-16 get-lt-16 {<index>|*} Displays 16 switching database entries starting at index ( continue from the last displayed index). SYS_console>get-lt-16 10 Entry —— MAC Address —— LOCK SELF...
  • Page 56 C H A P T E R Console Command Reference find-lt-addr find-lt-addr <mac_address> Searches for a MAC address in the switching database and displays its description, if found. SYS_console>find-lt-addr 00-40-05-2B-16-3D Entry ---- MAC Address ---- LOCK SELF DPORT MGMT ============================================================== 00-40-05-2B-16-3D del-lt-entry del-lt-entry <index>...
  • Page 57: Custom Filtering

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch get-lt-age Displays the switching database aging time in seconds. This is the amount of time the switch stores a device’s MAC address before clearing it from the database. An entry whose MAC address doesn’t appear in the source field of an incoming packet for this period of time is discarded.
  • Page 58 C H A P T E R Console Command Reference SYS_console> get-lt-filter 00aa00a5898b 00-AA-00-A5-89-8B LOCK_OFF SELF_OFF --- VIRTUAL LAN ----- SRC PORT to : MGMT P7 P8 P9 P10 P11 P12 ================================================================ get-lt-filter get-lt-filter <mac_address> Displays the custom filter for the specified MAC address. See the previous example.
  • Page 59: Vlan Commands

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch del-cf-entry del-cf-entry {run|nvram} <mac_address> <sport> Deletes the custom filter entry for address from source mac_address port Ports are deleted one at a time by entering the port sport.
  • Page 60 C H A P T E R Console Command Reference get-con-matrix Displays the current connectivity matrix for the switch. The first column is the source port. The other columns are destinations where frames from a given source port can be forwarded. Unlearned addresses (addresses that aren’t in the switching database) are forwarded to all ports marked with a + in the source port’s row.
  • Page 61 C H A P T E R Intel Express 10/100 Fast Ethernet Switch set-vbc-domain set-vbc-domain {run|nvram|all} <port_list> Establishes a virtual broadcast domain (VBD). is a list of port_list ports, separated by dashes, to group into a broadcast domain. set-vbc-domain all 2-5-6-7 This creates a VBD of ports 2, 5, 6, and 7.
  • Page 62 C H A P T E R Console Command Reference get-svlan-tbl get-svlan-tbl {run|nvram} Displays the table of defined SVLANs. SYS_console> get-svlan-tbl run RUNTIME SECURITY VIRTUAL LANs TABLE ================================ SVLAN ID P10 P11 P12 =========================================================== In this example, ports 1, 2, and 3 are an SVLAN and ports 1, 2, and 5 are an SVLAN.
  • Page 63: Spanning Tree Commands

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch Spanning Tree Commands Spanning tree automatically configures a loop-free topology in a bridged environment. The spanning tree agent is implemented in conformance with the IEEE 802.1d standard. In most cases, the defaults work fine and you won’t need to change any parameters.
  • Page 64 C H A P T E R Console Command Reference get-stp get-stp Displays the current state of spanning tree (either enabled or disabled). By default, spanning tree is enabled in accordance with 802.1d. SYS_console> get-stp Running Spanning Tree engine is enabled Next session the Spanning Tree engine will be enabled set-stp set-stp {enable|disable}...
  • Page 65 C H A P T E R Intel Express 10/100 Fast Ethernet Switch get-st-pcfg get-st-pcfg Displays the spanning tree port parameter table. If spanning tree is disabled, parameters aren’t displayed. STP PORT TABLE ================ ID Prior State PathCost DesigRoot DesigCost...
  • Page 66 C H A P T E R Console Command Reference set-br-prio set-br-prio <priority> Sets the spanning tree bridge priority. Bridge priority forces a bridge to be selected as the root bridge, or as a designated bridge. The bridge priority is a value used in determining the identity of the root bridge. The bridge with the lowest value has the highest priority and will be selected as the root.
  • Page 67 C H A P T E R Intel Express 10/100 Fast Ethernet Switch set-br-fwdel set-br-fwdel <forward_delay> Sets the spanning tree bridge forward delay. Forward delay is the time interval in seconds spent waiting to change a port from its spanning tree preforwarding state to a forwarding state.
  • Page 68: Port Configuration Commands

    10 Mbps when no device is attached. One exception is between two • Full duplex mode: ON or OFF (default). Express 10/100 switches. A • Flow control: ON (default) or OFF. If you set a port to full duplex, special piece of information is...
  • Page 69: Statistics Commands

    If the port is in full-duplex mode, flow control is turned off. Flow control or full duplex (or neither) can be active, but not both. One exception is between two Express 10/100 Switches. SYS_console> set-port-fctrl 2 off Port 2 - flow control <off>...
  • Page 70 C H A P T E R Console Command Reference get-eth-cnt get-eth-cnt <port-number> Displays the Ethernet Statistics Counters for port . This is port-number almost identical to the Ethernet-like Statistics Group of the Ethernet MIB. SYS_console> get-eth-cnt 1 Ethernet Statistics for port 1 ================================= Transmit 2817886...
  • Page 71 C H A P T E R Intel Express 10/100 Fast Ethernet Switch get-rmon-cnt get-rmon-cnt <port> Displays the remote monitoring (RMON) statistics group 1 counters port SYS_console> get-rmon-cnt 1 Ethernet RMON Counters for port 1 ==================================================== etherStatsOctets : 942514513 etherStatsPkts...
  • Page 72 C H A P T E R Console Command Reference • packets lost (if flow control is disabled) or number of packets retransmitted by the originator due to flow control (if flow control is enabled). • packets or bytes forwarded to each port. For the port you specified, the number of packets or bytes represents filtered frames.
  • Page 73 C H A P T E R Intel Express 10/100 Fast Ethernet Switch get-mgm-brcnt Displays the counters for the management interface. Management counters are continually updated even when no devices are attached to the switch (this is why the port Xmt LEDs always blink). This information is useful for seeing how much traffic the management interface is generating compared to the rest of the switch.
  • Page 74: Chapter 4 Troubleshooting

    The sequence of events leading up to your problem. • Actions you have already taken. If you call Intel Customer Support, you have 90 days of free support after your first call. Thereafter, Intel offers several Intel Support Service options. See the inside back cover for more information.
  • Page 75: General Problems

    C H A P T E R Intel Express 10/100 Fast Ethernet Switch General Problems If you’re having problems with the switch, follow the steps below: Verify that your cables are wired correctly. This is the most common problem. Use a UTP crossover cable to directly connect to a repeater or another switch.
  • Page 76: Flow Control Problems

    C H A P T E R Troubleshooting Restore the switch’s defaults with the command and init-nvram then reset the switch with the command. cold-reset Flow Control Problems During times of peak network usage, you may occasionally see the Flow LED blink (for a description of the LED, see page 6). This is normal.
  • Page 77 Additionally, because it relies on collision detection, full duplex isn’t possible when flow control is enabled. The exception is between two Express 10/100 switches. A special piece of information added to packets traveling between switches accomplishes this.
  • Page 78: Appendix A Technical Information

    Technical Information This chapter contains detailed information on default port and switch configuration options, product specifications, and supported standards for SNMP and MIB features. Default Configuration System Internal software filename: flash12.hex Database aging time: 300 seconds SNMP: Read community: public Write community: private Authentication mode: enable Traps: none set...
  • Page 79 A p p e n d i x Intel Express 10/100 Fast Ethernet Switch Ports 1-8 Type: 10BASE-T/100BASE-TX (auto detecting), twisted-pair Ethernet (TPE) Duplex mode: Half Flow control: Ports 9-12 Not installed (see Accessories on next page) Console Manager Communications parameters: 9600 baud, 8-N-1...
  • Page 80: Specifications

    LANDesk Network Manager (Intel order code EC100SNMP). Network Manager is a Windows-based SNMP network management system designed to manage Intel hubs and switches. Network Management In-band and out-of-band SNMP with MIB II, private MIB and out-of- band serial console support.
  • Page 81 A p p e n d i x Intel Express 10/100 Fast Ethernet Switch General Indicators Displays Management activity, SNMP presence, power supply status, device failure detection. Boot and Configuration NVRAM configuration loaded on power up and fully downloadable. Firmware local or remote downloadable. BOOTP supported.
  • Page 82 A p p e n d i x Technical Information Electrical Specifications AC line frequency: 47Hz-63Hz Fuse: 100-120V/4A 200-240V/2A Power Cord Specifications 115 volt configuration: Minimum type SJT (SVT) 18/3, rated 250 Volts AC, 10 Amps with a maximum length of 15 feet. One end is terminated in an IEC 320 attachment plug, the other in a NEMA 5-15P plug.
  • Page 83: Snmp And Mib Support

    • RFC 1123, Requirements for Internet hosts, application and support. You can manage the Express 10/100 Switch with any SNMP Manager that conforms to the above standards. The Express 10/100 Switch implements an Intel Enterprise MIB. Download SWCH2MIB.EXE from the Intel Customer Support World Wide Web site (http://support.intel.com) or Intel’s FTP site (see...
  • Page 84: Limited Hardware Warranty

    Limited Hardware Warranty Intel warrants to the original owner that the hardware product delivered in this package will be free from defects in material and workmanship for one (1) year following the latter of: (i) the date of purchase only if you register by returning the registration card as indicated thereon with proof of purchase;...
  • Page 85: Limited Hardware Warranty

    (RMA) number either to the company from whom you purchased it or to Intel . If you ship the product, you must assume the risk of damage or loss in transit.
  • Page 86 Manufacturer Declaration This certifies that the Intel Express 10/100 Fast Ethernet Switch complies with the EU Directive 89/33/EEC, using the EMC standards EN55022 (Class A) and EN50082-1. This product also meets or exceeds EN 60950 (TUV) requirements. This product has been tested and verified to meet CISPR 22 Class A requirements.
  • Page 87 A p p e n d i x Intel Express 10/100 Fast Ethernet Switch Assurez vous que le système soit débranché de son alimentation ainsi que de toutes les liaisons de télécomunication, des réseaux, et des lignes de modem avant d’enlever le capot. Ne pas utiliser le système quand le capot est enlevé.
  • Page 88: Index

    Index 100 LED, 6 Cabling 100BASE-FX cabling requirements, 7 crossover cables, 4 100BASE-TX cabling requirements, 7 fiber optic, 7 maximum distances, 78 A–C null-modem cable, using, 6 requirements, 4, 7 Access restrictions straight-through, 8 creating virtual LANs (VLANs), 23 UTP (twisted-pair) requirements, 7 command, 47 command, 38 add-arp-entry...
  • Page 89 Intel Express 10/100 Fast Ethernet Switch Configuration (continued) Diagnostics, viewing the last failure, 40 network topology, 10 Distance limitations ports, 65 fiber optic, 7 samples, 10 UTP, 7 SNMP, 21 Electrical specifications, 79 subnet mask, 44 Environmental limits, 79 switch, 15–29, 31–70...
  • Page 90 Intel Express 10/100 Fast Ethernet Switch command, 70 IP address get-mgm-brcnt command, 56 associating with a MAC address, 47 get-nv-cfilt command, 56 displaying, 43 get-nv-cftbl command, 22, 65 for SNMP, 2, 21 get-port-cfg command, 68 setting, 44 get-rmon-cnt command, 41...
  • Page 91 Intel Express 10/100 Fast Ethernet Switch M–O Quick Start, 1, 2 Rack mount installation, 4 MAC address Rcv (Receive) LED, 5 associating with an IP address, 47 Remote access, 16 displaying, 39 Repeaters Management, accessing, 16 cabling for, 9 Mgmt (Management) LED, 6...
  • Page 92 Intel Express 10/100 Fast Ethernet Switch command, 66 Specifications (continued) set-port-fctrl command, 38 status indicators, 77 set-prompt command, 64 switching database, 77 set-prt-enb command, 64 Speed, setting for a port, 66 set-prt-pcost command, 64 Standards supported, 78, 80 set-prt-prio command, 42...
  • Page 93 Intel Automated Customer Support You can reach Intel’s automated support services 24 hours a day, every day at no charge. The services contain the most up-to-date information about Intel products. You can access installation instructions, troubleshoot- ing information, and general product information.

This manual is also suitable for:

Express 100

Table of Contents