Kenwood TK-390 Service Manual page 47

Uhf fm transceiver
Hide thumbs Also See for TK-390:
Table of Contents

Advertisement

TK-390
Item
Condition
22. BATT
1) Set panel test mode
detection
CH No. : 3
check
Signalling No. : 1
BATT terminal voltage : 5.7V
PTT : ON
2) BATT terminal voltage : 6.5V
PTT : ON
Receiver Section
Item
Condition
1. AF level
1) Set panel test mode
check
CH No. : 3
Signalling No. : 1
SSG freq. : Each freq.
output : –53dBm/501µV
MOD. : 1kHz
DEV. : 3kHz
2) Turn the toggle SW to the
right (narrow)
SSG freq. : Each freq.
output : –53dBm/501µV
MOD. : 1kHz
DEV. : 1.5kHz
2. Hum and
1) Set panel test mode
noise ratio
CH No. : 3
check
Signalling No. : 1
SSG output : –53dBm/501µV
2) Turn the toggle SW to the
right (narrow)
SSG output : –53dBm/501µV
3. BPF coil
1) Set panel test mode
CH No. : 2
Use this
Connect the spectrum
adjustment
analyzer to TP3.
procedure
Signalling No. : 1
after replace-
Push Orange to 3 point
ing any of
adjustment mode
the BPF
Select SNS 25
coils
L
46
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Panel
ANT
DC VTVM Bottom BATT
terminal
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Panel
ANT
AF VTVM Side
Universal
Oscilloscope
Distortion
meter
Audio
analyzer
Tracking
Panel
ANT
TX-RX L205
generator
Spectrum TX-RX TP3
analyzer
Adjustment
Parts
Method
Check
Cannot transmit
LED (TX) blinks
Transmit
Adjustment
Parts
Method
Check
0.63V± 0.3V
3% or less
0.63V± 0.3V
5% or less
42dB or more
37dBm
Adjust the BPF coil so that the waveform is peaked.
L210
The frequency with the peak waveform does not
have to be the center frequency.
After finished peaking the waveform, perform a
3 point adjustment and set for maximum sensitivity.
RX BPF 0-10
REF –10.0dBm
ATT 10dB
10dB/
Center
TG LEVEL
–30dBm
RBW
300kHz
VBW
10kHz
SWP
70ms
CENTER 470.0MHz
Specifications/Remarks
Specifications/Remarks
A write B blank
MKR
443.6MHz
–31.07dBm
Hi
Low
SPAN 100.0MHz