3-3. Group Setting Mode
Set data for each Group while in this mode. After first
entering Self programming mode, select the "GROUP" dis-
play with [Top 1] [Top 2] and press [PTT] to set Group Set-
ting mode. Once in Group Setting mode, select the group
that needs setting with the [Top 1] [Top 2] keys and press
[PTT]. Next select the channel for setting with the [Top 1]
[Top 2] keys and press [PTT]. The setting items and setting
data will then appear so reset the data with the [Top 1]
[Top 2] keys and press [PTT]. When finished, the display
shifts to the next setting item. After finished setting all
items press [PTT] to return to next Group selection.
No.
Function name
Display
Select Group
GRP 1
1
Battery save
BATT L
2
Time out timer
TOT 60
3
TOT pre alert
TOT.P 10
4
TOT rekey time
TOT.K 2
5
TOT reset time
TOT.S 2
6
Group Delete/Add
D/A ADD
7
Signalling
SIG AND
• Operation
1. Select the setting value with the [Top 1] [Top 2] keys.
2. Press the [PTT] and the selected value is backed up and
operation shifts to the next item for setting.
3. Press [Side 2] on the Group selection screen in order to
return to the Self programming mode initial display.
• Note
1. Different sample displays are shown.
2. Setting item No.s are displayed with a 7-segment 2-digit
figure on the LCD.
3. Self programming mode cannot be set when set to Dis-
able with the FPU.
• Flow Chart
Self programming mode
Group setting mode
Group selection
[Side 2]
1. Battery save
[Side 2]
2. Time out timer (TOT)
[Side 2]
3. TOT pre-alert
[Side 2]
4. TOT rekey time
[Side 2]
5. TOT reset time
[Side 2]
6. Scan group Delete/Add
[Side 2]
7. Signalling AND/OR
[Side 2]
[Side 2]
REALIGNMENT
Remarks
1~160
OFF, Short, Mid, Long
OFF, 30s~300s (30s step)
OFF, 1s~10s (1s step)
OFF, 1s~60s (1s setp)
OFF, 1s~15s (1s step)
Delete, Add
AND, OR
[Top 1] [Top 2]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
[PTT]
3-4. Function Setting Mode
This mode allows making function settings for the trans-
ceiver. After first entering Self programming mode, select
"FUNC" display with [Top 1] [Top 2] and then press [PTT] to
set this mode. Function setting items are listed below.
No.
Function name
1
Power on tone
POW.T 15 (or C)
2
Control tone
CON.T 15 (or C)
3
Warning tone
WAR.T 15 (or C)
4
Alert tone
ALR.T 15 (or C)
5
Minimum volume
MIN.V 8
6
Battery warning
BATT ON
7
Busy LED
B.LED ON
8
TX LED
T.LED ON
9
Invert Display
LCD ON
10
Priority 1
P1 NONE
11
Priority 1 group
1.–1
12
Priority 1 channel
1–1.
13
Priority 2
P2 NONE
14
Priority 2 group
1.–1
15
Priority 2 channel
1–1.
16
Revert channel
REVT 1
17
Squelch level
SQ.LV 15
• Operation
1. Select the setting value with the [Top 1] [Top 2] keys.
2. Press the [PTT] and the selected value is backed up and
operation shifts to the next item for setting.
3. Press [Side 2] on the Group selection screen in order to
return to the Self programming mode initial display.
• Note
1. Different sample displays are shown.
2. Setting item No.s are displayed with a 7-segment 2-digit
figure on the LCD.
3. Self programming mode cannot be set when set to Dis-
able with the FPU.
TK-390
Display
Remarks
Continuas, 0~31
Continuas, 0~31
Continuas, 0~31
Continuas, 0~31
0~31
Disable, Enable
OFF, ON
OFF, ON
Disabel, Enable
None, Selected, Fixed
1–1~10–16
(Priority 1= In fixed)
None, Selected, Fixed
1–1~10–16
(Priority 2= In fixed)
1~8
1 : Selected
2 : Last called
3 : Last used
4 : Sel+Talk back
5 : Priority 1
6 : Priority 1+Talk back
7 : Priority 2
8 : Priority 2+Talk back
0~15