TK-390
Item
Condition
11. QT
1) Set panel tuning mode
deviation
CH No. : 3
adjustment
Signalling No. : 1
(wide)
MIC input : OFF
Select QTDV
in panel tuning mode
Deviation meter filter setting
LPF : 3kHz
HPF : 50Hz
De-emphasis : 750µs
PTT : ON
12. QT
1) Set panel tuning mode
deviation
CH No. : 3
adjustment
Signalling No. : 1
(narrow)
MIC input : OFF
Select QTDV
in panel tuning mode
Turn the toggle SW to the
right (narrow)
Deviation meter filter setting
LPF : 3kHz
HPF : 50Hz
De-emphasis : 750µs
PTT : ON
13. DQT
1) Set panel test mode
deviation
CH No. : 3
adjustment
Signalling No. : 1
(wide)
Select DQDV
in panel tuning mode
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
PTT : ON
14. DQT
1) Set panel tuning mode
deviation
CH No. : 3
adjustment
Signalling No. : 1
(narrow)
Select DQDV
in panel tuning mode
Turn the toggle SW to the
right (narrow)
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
PTT : ON
15. DTMF
1) Set panel test mode
deviation
CH No. : 3
adjustment
Signalling No. : 1
(wide)
Select DTDV
in tuning mode
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
44
Measurement
Test-
Unit
equipment
Power meter Panel
Deviation
meter
Oscilloscope
∗ ∗ ∗
AG
Side
AF VTVM
∗ ∗ ∗
∗ ∗ ∗
∗ ∗ ∗
∗ ∗ ∗
Adjustment
Terminal
Unit
Parts
ANT
Panel
Top1/
0.75kHz
Top2
Universal
0.375kHz
0.75kHz
0.375kHz
3.0kHz
Specifications/Remarks
Method
± 0.05kHz
± 0.05kHz
± 0.05kHz
± 0.05kHz
± 50Hz

Advertisement

Table of Contents
loading