Table 5. Firmware Error Codes. (continued)
Error Code Description
2602 0001 Invalid PCI adapter vendor ID
2602 0002 Invalid PCI adapter device ID
2602 0003 Invalid PCI adapter class code
Action/
Possible Failing FRU
1. Move adapter to another slot
(behind a different PCI bus).
2. Check for available firmware
updates for adapter. Apply update
if available.
3. Run AIX diagnostics on adapter.
Replace if indicated.
4. Replace adapter.
5. Check for system firmware
updates. Apply if update
available.
6. Replace primary I/O backplane
Location: U0.1-P1
1. Move adapter to another slot
(behind a different PCI bus).
2. Check for available firmware
updates for adapter. Apply update
if available.
3. Run AIX diagnostics on adapter.
Replace if indicated.
4. Replace adapter.
5. Check for system firmware
updates. Apply if update
available.
6. Replace primary I/O backplane
Location: U0.1-P1
1. Move adapter to another slot
(behind a different PCI bus).
2. Check for available firmware
updates for adapter. Apply update
if available.
3. Run AIX diagnostics on adapter.
Replace if indicated.
4. Replace adapter.
5. Check for system firmware
updates. Apply if update
available.
6. Replace primary I/O backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index