Refrigerant Cycle Diagram - Air-Con 38B Service Manual

Room air conditioner split wall-mounted type
Table of Contents

Advertisement

Connecting the cables
The power cord of connect should be selected according to the following specifications sheet.
Unit
7K
mm2
1.0
1.0
Pipe length and the elevation
Capacity
Pipe size
Btu/h
GAS
3/8'' (φ9.52)
9K-12K
1/2'' (φ12.7)
18K-22K
5/8'' (φ15.88)
24K-28K
Caution:Capacity is base on standard length and maximum allowance length is base of reliability.Oil
trap should be install per 5-7 meters.
4、
Indoor unit and outdoor unit explosion diagram and spare parts list(see explosion diagram file)

5. Refrigerant cycle diagram

5.1 Cooling only
Grade
9K
12K
18K
1.5
2.5
Standard length
LIQUID
1/4'' (φ6.35)
1/4'' (φ6.35)
3/8'' (φ9.52)
24K
28K
2.5
2.5
Max.
(m)
Elevation
B (m)
3.5
5
4
10
5
15
9
Max.
Additional
Elevation
refrigerant
A (m)
(g/m)
10
30
15
30
20
65