Air-Con 38B Service Manual page 25

Room air conditioner split wall-mounted type
Table of Contents

Advertisement

≤3
(2)end defrost condition(meet one of follows)
a、defrost time have fifteen minutes.
b、defrost relay turn on; (>8℃)
c、press ON/OFF key in defrost process.
3. Outdoor sensor for defrost
① unit start defrost shall meet one of the following conditions:
a. compressor cumulate running time over 30 minutes and it continuous running over 3 minutes, the
temperature of coil pipe of the outdoor units is equal to or less than -15℃ for one minutes (Tp
b. compressor cumulate running time over 40 minutes and it continuous running over 3 minutes, the
temperature of coil pipe of the outdoor units is equal to or less than -5℃ for one minutes (Tp
c. Air conditioner first power on or it wait over 30 minutes ,the temperature of coil pipe of the outdoor units is
equal to or less than -2℃ (Tp
②end defrost condition(meet one of follows)
a. the temperature of coil pipe of the outdoor units is more than 15℃ (Tp
b. defrost time have fifteen minutes.
TP2
com pr essor
out door
bl ow er f an
door
bl ow er f an
80
≤-15℃)
2
Tr
25
2
≥-15℃).
2
≤-15℃).
2
≤-15℃).