SOLUTION PUMP REMOVAL
1. Turn main power off.
2. Disconnect the two pump wire leads.
3. Remove (4) screws holding the pump to the main frame.
4. Lift the pump out to access solution inlet and disconnect from the pump head.
Refer to the pump drawing page 16 for replacement parts.
BELT / BRUSH ASSEMBLY REMOVAL
1. Turn main power off.
2. Use brush height adjustment lever to lower brush to its lowest
position.
3. Remove the belt guard.
4. Now remove the brush pulley guard.
5. Loosen tension in belt by moving idler pulley clockwise.
Simultaneously remove belt from motor pulley, while holding idler
pulley. Once belt has been removed from motor pulley, slowly let
idler pulley rotate counterclockwise. Do not loosen spring.
6. Remove the screw from each end of the brush shaft.
7. Swing the brush assembly out of the housing to remove the belt.