PRG Best Boy 4000 Service Manual page 67

Spot luminaire
Table of Contents

Advertisement

CAUTION:
NEVER touch or adjust the brass spring-loaded standoff. It is set at the factory.
2-56 x 3/16" PPSS Screw (2)
- Apply Loctite 222
Zoom Sensor (G3)
3/16" Hex
Standoff (2)
Lens Group 3
G3
Figure 3-32: Removing Zoom Sensors 1 & 3
BEST BOY 4000
Use anti-static precautions
CAUTION:
when working with PC boards.
Lens Group 1
G1
2-56 x 3/16" PPSS Screw (2)
Zoom Sensor (G1)
®
SPOT LUMINAIRE FIELD SERVICE MANUAL