Troubleshooting; Errors; Status Indications; Comm Led - PRG Best Boy 4000 Service Manual

Spot luminaire
Table of Contents

Advertisement

TROUBLESHOOTING

Errors

Status Indications

The STATUS panel at the Home screen will report overall luminaire conditions as follows:
+
CALIBRATION (yellow)
+
OK (green)
+
ERROR (red)
+
LOCKED (white)
Pressing the STATUS panel will bring up a detailed Status screen as shown below:
The Status screen will indicate which specific mechanisms, if any, have errors. It also provides a log of systems
activity. The Status screen operates as follows:
+
Mechanisms - displays mechanism status. Mechanism names will be shown in yellow during calibration, green if
okay, and red if an error exists. If an error exists, press the Mechanisms panel to bring up the Recalibration
screen. Try recalibrating the mechanism(s) that is reporting the error.
+
Log - displays system log. Use touchscreen arrows to scroll up or down. Press CLR to bring up Clear Log Yes/No
options.

Comm LED

In the case of a mechanism error, the Comm LED on the input panel will flash either red or green (depending on the
comm state).
Comm LED
COMM
WAKE
®
16
BEST BOY 4000
SPOT LUMINAIRE FIELD SERVICE MANUAL
DMX
Figure 2-1: Comm LED
AC IN
100 -240 VAC
THRU
ETHERNET
50 / 60 Hz
IN
12A Max