If the projector shall be lowered from the ceiling or high joists, professional trussing systems have to be
used. The projector must never be fixed swinging freely in the room.
Caution: Projectors may cause severe injuries when crashing down! If you have doubts concerning the
safety of a possible installation, do NOT install the projector!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the projector's
weight.
When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
Use 2 appropriate clamps to rig the fixture on the truss.
Follow the instructions mentioned at the bottom of the base.
Make sure that the device is fixed properly! Ensure that
the structure (truss) to which you are attaching the fixtures is secure.
The maximum drop distance must never exceed 20 cm.
A safety rope which already hold the strain of a crash or which is defective must not be used again.
Before taking into operation for the first time, the installation has to be approved by an expert!
DANGER OF FIRE!
CAUTION!
DANGER TO LIFE!
24/58
The
Moving-Head
can
directly on the stage floor or rigged in
any orientation on a truss without
altering its operation characteristics
(see the drawing).
The fixture's base enables to be
mounted in two ways. Use the clamps
with screws M10 or M8 - check the
base bottom.
For overhead use (mounting height
>100 cm), always install a safety-rope
that can hold at least 12 times the
weight of the fixture. You must only use
safety-ropes with quick links with screw
cap. Pull the safety-rope through the
attachment eyelet and over the trussing
system or a safe fixation spot. Insert the
end in the quick link and tighten the
fixation screw.