12.8 Powerful Operation

š
To achieve the setting temperature quickly.
š
When powerful operation is set, the setting temperature will be automatically decreased 3°C internally against
the present setting temperature (Lower temperature limit: 16°C).
š
This operation automatically running under Shi fan speed (Cooling), Lo- Fan Speed (Soft Dry) is applicable for
C7MKP-7, C9MKP-7 and C12MKP-7 only.
š
Vertical Airflow Direction:
In "Manual" setting, the vane will automatically shift down 10° lower than previous setting.
o
In "Auto" setting, the vane will automatically swing up and down. However the lower limit will be shifted 10°
o
downward.
š
Powerful operation stops when:
Powerful/Quiet button is pressed again
o
Powerful operation has operate for 4 hours
o
Stopped by OFF/ON operation button.
o
Timer OFF activates
o
Operation mode is changed
o

12.9 Quiet Operation

(For Cooling Operation or cooling region of Soft Dry Operation)
š
To provide quiet cooling operation condition.
š
Once the Quiet Operation is set at the remote control, the Quiet LED brightness will be dimmed. The sound level
will reduce around 2dB(A) for Lo fan speed or 3dB(A) for Hi/Me fan speed against the present operation sound
level.
š
Dew formation become severe at Quite Lo Cool, therefore Quiet Lo cool operated only for 1 hour 30 minutes
(1 hour QLo, 30 minutes QLo + 80rpm) (for C7MKP-7, C9MKP-7 and C12MKP-7) and Quiet Lo cool operated
only 1 hour 30 minutes (1 hour QLo, 30 minutes QLo + 50 rpm) (for C18MKP-7 and C24MKP-7).
š
Manual Airflow Direction:
RPM control during Lo cool
o
(For C7MKP-7, C9MKP-7 and C12MKP-7)
(For C18MKP-7 and C24MKP-7)