PIN
PORT NAME
No.
100
RESET
Reset enable signal input.
Noise signal from the IF IC (Left band;
101
L_SQL
IC15).
102
CL_SFT2
Clock frequency shifting signal.
Noise signal from the IF IC (Right band;
105
R_SQL
IC18).
122
R_DATA
Data lines for the control unit.
123
TX_DATA
Data lines for the control unit.
127
TX232
Data bus for RS-232C communication.
128
RX232
Data bus for RS-232C communication.
129
DA_CK
Serial clock signal to the D/A converter.
130
DA_DATA
Serial data to the D/A converter.
134
DA_STB
Strobe signal to the D/A converter.
135
R_R5C
RX circuits (Right band) control signal.
Power line control signal to the 375−550 MHz
136
R400_S
band RF circuit (Right band).
Power line control signal to the 810−1000
137
R_RX800
MHz band RF circuit (Right band).
AM-demodulator circuit (Right band)
138
R_AMC
control signal.
143
DTMSD
Data to the DTMF decoder (IC56).
144
DTMCK
Clock signal to the DTMF decoder (IC56).