Replacing a hot-swap fan

The following notes describe information that you must consider when replacing a
hot-swap fan in the server:
v The server comes with six hot-swap fans.
v You do not need to turn off the power to the server to replace a hot-swap fan.
Attention:
Complete the following steps to replace a hot-swap fan:
1. Review the safety information beginning on page v, and "Installation guidelines"
2. Remove the top cover (see "Removing the cover and bezel" on page 13).
3. Open the fan-locking handle by sliding the orange release latch in the direction
4. Pull upward on the free end of the handle to lift the fan out of the server.
5. Open the locking handle on the replacement fan, lower the fan into its socket,
6. If you have other options to install or remove, do so now; otherwise, go to
If a fan fails, replace it within 48 hours to help ensure proper cooling.
on page 11.
Attention:
To ensure proper system cooling, do not leave the top cover off the
server for more than 2 minutes.
of the arrow.
Fan Error
LED
Hot-swap fan 1
Hot-swap fan 2
and rotate the handle to the locked position.
"Completing the installation" on page 35.
Hot-swap fan 5
Hot-swap fan 6
Hot-swap fan 3
Hot-swap fan 4
Chapter 2. Installing options