3.4
3.4.1
12
Note: The BS370 base station is not for new delivery, product is in
passive sustaining.
For more information about transmission pattern see chapter 6 Appendix
B: Radio base station signaling pattern on page 44.

Total area coverage

The base station coverage depends on the following factors:
The indoor cell size in offices may be in a range of 10 - 40m radius,
see figure 6 Example of maximum coverage of one base station on
page 15.
The cell size in exhibition- or production halls is up to 200m radius
(when free line of sight).
The outdoor cell size in free space may be up to 300m radius.
The base stations may partially cover floors immediately above and
below as well. The useful range through floors and ceiling varies
between 0 and 8m (2 floors) radius See figure 12 Measurement of
a typical cell size. on page 23
In this section different configurations are shown. In normal environ-
ments, all these configurations are mixed, due to the building's construc-
tion, the users movement and usual location.
Note: This section is based on standard antennas.
Minimum roaming and hand over traffic configuration
To keep the roaming and hand over traffic to a minimum, to avoid
roaming and hand over between floors and get best possible radio
performance it is preferred that the base stations are placed vertically
above each other, see figure 4 Example of a high call configuration.
ELU31 has 32 B-channel configuration. on page 14. This configuration
will also create a safer configuration in case a base station is out of
order.
5/1531-ANF 901 14 Uen D3 2013-11-28