8. Rotate the AP-5131 chassis 45 degrees clockwise, or about 10 o'clock.
9. Push the back of the AP-5131 chassis on to the bottom of the ceiling T-bar.
CAUTION
10. Rotate the AP-5131 chassis 45 degrees counter-clockwise.
The clips click as they fasten to the T-bar.
11. The AP-5131 is ready to configure. For information on basic AP-5131 device configuration,
see "
Configuring "Basic" Device Settings
NOTE
3.4.4
Above the Ceiling (Plenum) Installations
An AP-5131 above the ceiling installation requires placing the AP-5131 above a suspended ceiling
and installing the provided light pipe under the ceiling tile for viewing the rear panel status LEDs of
Ensure the safety wire and cabling used in the T-Bar AP-5131
installation is securely fastened to the building structure in order to
provide a safe operating environment.
If the AP-5131 is utilizing remote management antennas, a wire cover
can be used to provide a clean finished look to the installation. Contact
Motorola for more information.
" on page 25.