Installation

IMPORTANT: Before installation and usage read
all the instructions and make sure that the
voltage (V) and the frequency (Hz) indicated on
the rating plate are exactly the same as the
voltage and frequency in your home. The rating
plate can be found on the front left edge of the
inside of the wine cabinet.
The manufacturer declines all responsibility in the event of the installer
failing to observe all the accident prevention regulations in force,
which are necessary for normal use and the regular operation of the
electric system.

Electrical connection

YOUR WINE CABINET IS INTENDED FOR FITTED AND
PERMANENT INSTALLATION.
We recommend that the appliance is connected by a qualified
electrician, who is registered on the E.W.R.B. web site and who will
comply
with
the
regulations.
o Your wine cabinet comes supplied with a 10 amp moulded lead
with an AS/NZS 3112 approved plug.
o The wiring in the mains lead is coloured as follows:
Brown
Blue
Green and yellow
o As the colours of the wires in the appliance's mains lead may not
correspond with the coloured markings identifying the terminals
in your spur box, please proceed as follows:
The brown wire must be connected to the terminal marked "L"
(live), or coloured red.
The blue wire must be connected to the terminal marked "N"
(neutral), or coloured black.
The green and yellow wire must be connected to the terminal
marked "E" (earth), or by the earth symbol, or coloured green
and yellow.
AS/NZS
3000
Wiring
Live
Neutral
Earth
Regulations
and
local
19