Small Repairs - Kranzle K1622 Operating Manual

High-pressure cleaners
Hide thumbs Also See for K1622:
Table of Contents

Advertisement

Nozzle dirty or sticky!
Pressure gauge does not show full pressure.
Water comes out in spurts.
If you do not use the high-pressure cleaner
for some time the valves can stick
When a valve is blocked,
Open the valve
with a socket
and remove the
dirt from the valve
- the valve inside
must be closed.
Retighten the
valve screw
18

Small repairs -

wrench...
the gauge
shows little
pressure or
no pressure
at all,
and remove the
valve screw, the
valve and the
o-ring.
Replace the rubber o-ring.
Now it works
...and repeat
as well as
on all 6 val-
ves.
The high-pressure
hose vibrates.
or the high
pressure
hose vibrates!
Straighten a
paper clip...