Control panel

Control panel
All settings are made from the control panel. It also displays heat production
statistics and information about different alarms. When you have made your
settings, the control panel makes sure they are saved in the control unit
Rego 637 to carry out your wishes.

Controls and status lamps

Power switch (ON/OFF)
You start and stop the heat pump using the power
switch button.
Lamp on: The heat pump is on.
Lamp fl ashes: The heat pump is off.
Operating status
Lamp on: The heat pump (compressor) is
operational.
Additional heat status
Lamp on: The heat pump is using additional heat
from an electric cassette.
Hot water status
Lamp on: The heat pump is heating water in the
heater.
Lamp fl ashes: The heat pump has a hot water
peak or is producing extra hot water.
Alarm status
Lamp fl ashes: A fault has occurred in the heat
pump.
Lamp on: The alarm has been acknowledged, but
the fault remains.
Temperature
Temperature
Pressing once gives a shortcut to the most frequent
temperature settings.
Info
Info
Pressing once gives continuous information about the
heat pump's and additional heat's operating conditions.
Menu
Menu
Press once to enter the main menu. The main menu
contains all setting menus and temperature displays.
Control panel
Status lamps
Menu dial
Menu buttons
Menu display
12