For setting the shutter speed using the DIP switches
No HD/VD input (Internal synchronization)
1
100 µ s to 250 ms
Trigger*
1
Exposure time (Te)*
Internal VD*
4
T: T=under 10
Video out
WEN
*1 This is a signal input from outside.
*2 The exposure time (Te) is determined by the
setting of the DIP switches.
For details, see Page 10.
*3 The normal operation state is chosen when the
trigger pulse width is 1/3 s or more. The trigger
falling edge restores the external trigger shutter
operation. In this case, the area between the falling
edge of a trigger pulse and the subsequent 50 ms
period is an external trigger input inhibition area.
There is no guarantee of operation for any triggers
input in this period.
*4 The internal VD signals are output as long as there
is no external input and the HD/VD signal
input/output switch on the rear panel is set to INT.
External trigger shutter operation
2
2
Exposure time (Te)*
T: T=10
s or more*
m
5
s*
m
1
2
250 H (EIA)
250 H (EIA)
293 H (CCIR)
293 H (CCIR)
Normal
3
operation*
Trigger pulse width*
3
2
5
*5 An image is output when an internal VD signal
falls 10 ms or more after a trigger pulse rises (2
and 3 in the figure). If the period from the
trigger rising edge to the internal VD falling edge
(T in the figure) is under 10 ms, it is not defined
whether the image is output for the internal VD
falling edge or the image is output for the next
internal VD falling edge. (1 in the figure shows
that the image is output for the next internal VD).
In this case, see WEN since the image and WEN
make up a pair.
(The internal VD falling edge and the beginning
of the equivalent pause in the V period of the
SYNC have the same phase.)
Note
An image will not be output correctly if another
trigger is input before the image for the previous
trigger is output.
Mode Setting
Mode transition state
External input
External trigger
inhibition area
shutter operation
(50 ms)
3
Exposure time
2
(Te)*
T: T=10
s or
m
more*
5
3