When Set To Mode 2 - Sony XC-ES50/50CE Technical Manual

Ccd black-and-white video camera module
Hide thumbs Also See for XC-ES50/50CE:
Table of Contents

Advertisement

When set to Mode 2

For setting the shutter speed using the trigger pulse width
External trigger shutter operation
1
Trigger*
Exposure time (Te)*
Video out
1 H to 2 H
*
4
WEN
250 H (EIA)
293 H (CCIR)
*1 This is a signal input from outside. The trigger
input frequency must be [Trigger pulse width + 1
field + 2 H frequency] or more. The operation is
not guaranteed for shorter frequencies. If invalid
data is input, normal operation is resumed several
Vs after entering the correct data.
*2 Exposure time (Te)
Te = Trigger pulse width +97 µ sec (EIA)
Te = Trigger pulse width +120 µ sec (CCIR)
(The effective trigger pulse width for the external
trigger shutter operation is between 2 µ s and 1/4 s.)
*3 The normal operation state is chosen when the
trigger pulse width is 1/3 s or more. The trigger
falling edge restores the external trigger shutter
operation. In this case, the area between the falling
edge of a trigger pulse and the subsequent 50 ms
period is an external trigger input inhibition area.
There is no guarantee of operation for any triggers
input in this period.
Trigger pulse width*
2
250 H (EIA)
293 H (CCIR)
Mode transition state
Normal operation*
3
3
*
5
*4 A VD signal is generated after 1 H to 2 H from the
trigger falling edge, then the image is output
synchronized with the VD generation.
*5 When the external trigger shutter mode changes to
the normal operation mode, one WEN signal is
output.
Mode Setting
External input
inhibition area
External trigger
(50 ms)
shutter operation
Exposure time
2
(Te)*
1 H to 2 H
4
*
250 H (EIA)
293 H (CCIR)
20