Chapter 3: Troubleshooting & Maintenance
Alarm message
NO DATA
NO PILOT
NO RUDREF
RG FAIL
NO SPD
NO COMP
NO WIND
SEATALK and FAIL

3.2 Maintenance

Important

Before attempting any maintenance procedure on the SPX-5 Sport system, ensure
the boat is securely moored alongside and that power to all system components is
switched off.
CAUTION: Avoid damage when cleaning
Do NOT use solvent or abrasive cleaners on any SPX-5 Sport system
components.

Spare parts

CAUTION: Do not dismantle SPX-5 Sport system products
The SPX-5 Sport system does not contain any user serviceable parts
other than those specified below, and so should be serviced only by
authorized Raymarine service technicians.
The only user-replacable components in the SPX-5 Sport system are the Course
Computer fuses, and these are available from your Raymarine dealer:
Fuse F1 - 15 A (power in fuse). Part number 15454.
Fuse F2 - 2 A (SeaTalk fuse). Part number 15455.
If any other parts require servicing or replacement, please contact your Raymarine
authorized service agent.
Possible cause and remedy
Caused by any of the following situations:
• the compass is not connected
• the SPX-5 Sport system is in Track mode and:
• is not receiving navigation data, or
• the position sensor (GPS) is receiving a low strength signal – prob-
lem will clear when the signal improves
Check connections to the compass and navigator.
Note: The SPX-5 Sport system stops adjusting the heading as soon
as it loses data.
The Pilot Controller is not receiving data from the SPX-5 Sport system
computer. Check connections and check the Course Computer is
switched on.
Only applicable if rudder reference option is fitted. Possible fault with
rudder position sensor – check connections.
GyroPlus yaw sensor has failed. Call a Raymarine service agent.
No speed data.
No compass data.
No wind data.
The Pilot Controller cannot transmit data to the SeaTalk system.
Make sure all SeaTalk cables are connected properly.