Accessing response setup

You can access the User calibration mode only from Standby mode, so to set the
response level:
1. Ensure the SPX-5 Sport system is in Standby mode, then hold down standby for
2 seconds. The display will change to show DISPLAY CAL.
2. Press disp once. The display will now show USER CAL.
3. Press auto to enter User calibration.
The Response setup page is displayed.
4. To access other User calibration pages, press disp to scroll through the
calibration functions (described below).
5. Use the -1, +1, -10 and +10 buttons to change the value of each function you want
to change.
6. When you have made all the changes you want to make, hold down standby for
two seconds to exit calibration mode and save changes.
SmartPilot X-5 Sport Operating Guide