Quickscan Mobile Cradle Configuration; Quickscan Mobile Reader Configuration - Datalogic QuickScan Mobile Quick Reference Manual

Hide thumbs Also See for QuickScan Mobile:
Table of Contents

Advertisement

DATALOGIC

QUICKSCAN MOBILE CRADLE CONFIGURATION

The QuickScan Mobile cradle configuration can be performed in two ways:
either by sending configuration strings from the Host via the RS-232 or
USB-COM interface or by reading configuration barcodes with the reader.
Serial/USB-COM Configuration
By connecting the QuickScan Mobile cradle to a PC through an RS-232 or USB
cable (only USB-COM interface) it is possible to send configuration strings from
the PC to the reader. Using this method you can also send new configuration
strings from the PC to the reader or upgrade application software onto the
reader.

QUICKSCAN MOBILE READER CONFIGURATION

When the QuickScan Mobile cradle is connected and powered, configure the
®
QuickScan
Mobile reader by reading the following codes in the given sequence
and follow the instructions.
Note: for the numeric code selection of step 3, use the table at the end of this
Quick Reference Guide.
1.
2.
3.
All readers used in the same area must have different addresses.
4.
8
Restore QuickScan Mobile default
Ì$+$*oÎ
Enter configuration
Ì$+;Î
Set Radio Address
ÌRF8Î
four digits for the QuickScan Mobile Address
(from 0000 to 1999).
Exit and Save configuration
Ì$-?Î
+