Technical Features - Datalogic QuickScan Mobile Quick Reference Manual

Hide thumbs Also See for QuickScan Mobile:
Table of Contents

Advertisement

DATALOGIC
WEDGE DEFAULT SETTINGS (only for Quickscan M2 Type:130)
USA keyboard, caps lock off, caps lock auto-recognition enabled; num lock
unchanged, inter-character and inter-code delay disabled.
DATA FORMAT: code identifier disabled, code length not transmitted, no
header, terminator = ENTER, character replacement disabled, address
stamping disabled, address delimiter disabled.
IBM DEFAULT SETTINGS (only for Quickscan M2 Type:110)
DATA FORMAT: IBM Standard, code identifier disabled, no header, no
terminator
PEN DEFAULT SETTINGS
Interpret operating mode, minimum output pulse 600 µs, conversion to Code 39,
overflow medium, output level normal, idle level normal, inter-block delay
disabled.

TECHNICAL FEATURES

Electrical Features - READER
Battery Type
Time of recharge Lithium
Operating autonomy
Indicators
Max scan rate
Electrical Features - CRADLE
Supply voltage
Power consumption
LED Indicators
Optical Features
Sensor
Illuminator
Wavelength
Max. LED Output Power
LED safety class
Reading field
Max. resolution
PCS minimum
22
®
QuickScan
Mobile Reader and Cradle
1 Lithium battery 700 mAh
max 6 hours with USB cable
typical 20000 reads
LED, Beeper
235 scans/sec
5 VDC ± 5%
max. 4 W (charging)
Battery charging red
Charge completed green
Power / Data yellow
CCD solid state (2088 pixels)
LED array
630 ~ 670 nm
0.33 mW
Class 1 EN 60825-1
see reading diagram
0.10 mm, 4 mils
20% (Datalogic Test Chart)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents