2. Hardware Installation

Note: Please connect the computer configuring the TEW-455APBO to the
same switch/hub.
1. Remove the screw and washer
from the grounding hole using a
screwdriver.
2. Align one end of the grounding
wire over the hole. Then connect
the screw and washer back in.
3. Connect the green grounding wire
to a grounding object.
e.g. Earth Driven rod, Grounded
Electrical System, Building Frame.
4. Use a wire stripper to strip off
about 2 inches of the cable sheath
from one end of an Ethernet cable.
5. Insert the seal into the rear of the
clamp ring. Then insert the gasket
into the front end of the clamp ring.
6. Insert the body, the screw nut, the
sealing nut and clamp ring into the
stripped end of the cable.