Minimum Clearances To Combustible Surfaces - Vogelzang International BX26E Owner's Manual

Standard boxwood stove
Hide thumbs Also See for BX26E:
Table of Contents

Advertisement

LOCATING STOVE continued...
DASHED LINE SHOWS
HORIZONTAL CHIMNEY
CONNECTOR AND
ADDITIONAL FLOOR
PROTECTION REQUIRED
8"
SIDEWALL
NON-COMBUSTIBLE
CONSTRUCTION IN
ACCORDANCE WITH
NFPA 211
36"
8"
36"
Fig. 1 – Minimum Clearance Dimensions from Combustible Surfaces
5. Recheck clearances from the stove,
connector stove pipe, and corner clearances
using the illustrations (figure 1 & 2) and
your local building codes or fire protection
ordinances.
NOTE: Drywall faced with brick or stone must
be considered a combustible surface.
6. DO NOT INSTALL THIS STOVE IN A MOBILE
HOME, MANUFACTURED HOME, TRAILER OR
TENT – NO EXCEPTIONS! (HUD Federal
Standard: 24 CFR Ch.XX)
7. The clearances provided are minimum
dimensions determined by NFPA. Installation
of this stove must comply with the latest edi-
tion of NFPA 211 for reduced clearances and/
or your local building code rulings. Use which-
ever minimum dimensions are LARGEST.
Failure to follow these minimum clearance
requirements may result in an unsafe
installation and could cause a fire.
8. This stove is NOT a UL listed stove.
Page 4
/ BX26E
BACKWALL
36"
38"
NON-COMBUSTIBLE
CONSTRUCTION IN
ACCORDANCE WITH
NFPA 211
FLOOR
PROTECTOR
54"
(TOP VIEW)
CORNER CLEARANCES
36"
36"
Fig. 2 – Top View
Minimum Corner Clearances from
Combustible Surfaces
MINIMUM CLEARANCES
TO COMBUSTIBLE SURFACES
Unit to Sidewall ........................ 36 inches
Unit to Backwall ....................... 36 inches
Unit Corner to Wall .................... 36 inches
Pipe Connector to Backwall .......... 38 inches
Pipe Connector to Ceiling ............ 18 inches
CAUTION: KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS AWAY FORM THE
STOVE.
VGZ-006 / 031406