Download Print this page
Vogelzang International BX26E Owner's Manual

Vogelzang International BX26E Owner's Manual

Standard boxwood stove
Hide thumbs Also See for BX26E:

Advertisement

Quick Links

STANDARD BoxwooD STove
model BX26E
READ ALL INSTRUCTIONS CARE-
FULLY BEFORE STARTING THE
INSTALLATION OR OPERATING
THE STOVE. FAILURE TO FOLLOw
INSTRUCTIONS mAY RESULT IN
P R O P E R T Y DA m AG E , B O D I LY
INjURY, OR EVEN DEATH.

SAFETY INSTRUCTIONS

SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE mAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PERmITS,
RESTRICTIONS, AND INSTALLATION REqUIREmENTS FOR YOUR AREA.
READ ALL INSTRUCTIONS CAREFULLY.
1. The installation of this stove must comply
with your local building code rulings. Please
observe the clearances to combustibles (see
reference figures 1 & 2).
2. Do not install this stove in a mobile
home, manufactured home, trailer or tent
(NO EXCEPTIONS! per HUD Federal
Standard: 24 CFR Ch.XX).
3. Verify that the stove is properly installed
before firing the stove for the first time.
After reading these instructions, if you have
any doubt about your ability to complete
your installation properly, you must ob-
tain the services of a professional licensed
installer familiar with all aspects of safe
and correct installation. DO NOT use
temporary or makeshift compromises
during installation.
4. If any parts are missing or defective, please
notify the dealer or manufacturer immedi-
ately. DO NOT OPERATE A STOVE THAT
Tools necessary to complete the assembly of this product are as follows: (a) adjustable wrench
(b) flat blade screwdriver (c) Phillips screwdriver (d) pliers. Tools are not included.
VGZ-006 / 20100604
(save this manual for future reference)
Approximate assembly time is 45 minutes.
Owners manual
DO NoT USE THIS STOVE IN A
mOBILE HOmE, mANUFACTURED HOmE,
TRAILER OR TENT – NO EXCEPTIONS!
NOTE: THIS STOVE IS
NoT A UL LISTED STOVE.
IS MISSING ANY PARTS!.
5. Do not tamper with combustion air control
beyond normal adjustment capacities.
6. Always connect this stove to a chimney and
vent to the outside. Never vent to another room
or inside a building. DO NOT CONNECT
THIS UNIT TO A CHIMNEY FLUE SERV-
ING ANOTHER APPLIANCE.
7. DO NOT CONNECT a wood burning stove
to an aluminum Type B gas vent. This is not
safe. Use approved masonry or a UL 103 HT
Listed Residential Type and Building Heat-
ing Appliance Chimney. Use a 6" diameter
chimney or larger, that is high enough to
give a good draft. (See specifics in installation
instructions).
8. Be sure that your chimney is safely con-
structed and in good repair. Have the chimney
inspected by the fire department or a qualified
inspector. Your insurance company should be
able to recommend a qualified inspector.
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
continued on next page
Page 1
BX26E /

Advertisement

loading

Summary of Contents for Vogelzang International BX26E

  • Page 1: Safety Instructions

    STANDARD BoxwooD STove Owners manual model BX26E (save this manual for future reference) DO NoT USE THIS STOVE IN A READ ALL INSTRUCTIONS CARE- mOBILE HOmE, mANUFACTURED HOmE, FULLY BEFORE STARTING THE TRAILER OR TENT – NO EXCEPTIONS! INSTALLATION OR OPERATING THE STOVE.
  • Page 2 Clean with soap and warm water when stove is NOT hot. Do not use any acids or scouring soap, as these solvents wear and dull the finish. 16. While stove is in operation, all persons, Page 2 / BX26E VGZ-006 / 20100604...
  • Page 3: Bottom

    ASSEmblY INSTRUCTIONS NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of your wood stove and assumes no responsibility of any incidental or consequential damages. tools required materials required (NOTE: The following items are NOT included with your stove) Safety Glasses 1/8”...
  • Page 4 6” masonry chimney or a 6” i.d. listed chimney. Maximum 64 square inches. 4. Use 6” round black stove pipe, not galvanized stove pipe. Secure pipe to damper and each sec- Page 4 / BX26E VGZ-006 / 20100604.1...
  • Page 5 ......36 inches unit corner to Wall ....36 inches Pipe connector to backwall ..38 inches Pipe connector to ceiling .... 18 inches CAUTION: kEEP FURNISHINGS AND OTHER COmBUSTIBLE mATERIALS AwAY FORm THE STOVE. Page 5 VGZ-006 / 20100604 BX26E /...
  • Page 6: Connector Pipe Installation

    90° bends be used in the stovepipe installa- TO PURCHASE PIPE, VISIT YOUR LOCAL HARDwARE, HOmE OR BUILDING CEN- TER. SEE “LOCATING STOVE” PAGE 3 FOR ADDITIONAL SPECIFICATIONS. correct WroNG WroNG Fig. 3 – Stovepipe/Flue Connections Page 6 / BX26E VGZ-006 / 20100604...
  • Page 7 4. Never use a chimney to ventilate a cellar or basement. 5. Contact your local building authority for approved methods of installation and any necessary permits and/or inspections. Fig. 5 - Chimney Construction Through Attic Space Page 7 VGZ-006 / 20100604 BX26E /...
  • Page 8 Chimney Sweep, or a knowledgable inspector. Consult your insurance company if you cannot find a qualified expert. Fig. 7 - Chimney Connection to Firebox Through Masonry Wall continued on next page Page 8 / BX26E VGZ-006 / 20100604...
  • Page 9 National Fire Protection Association (NFPA) and request a copy of the latest editions of NFPA Standard 211 and NFPA Standard 908. Their ad- dress is: Battery March Park, Quincy, MA 02269. Fig. 8 - Fireplace Conversion Page 9 VGZ-006 / 20100604 BX26E /...
  • Page 10: Operating Instructions

    1. Always open draft damper before opening the feed door. 2. When adding fuel be careful not to smother the fire. continued on next page Page 10 / BX26E VGZ-006 / 20100604...
  • Page 11 (2) feet higher ately call the fire department. than any point of the roof within ten (10) feet. continued on next page Page 11 VGZ-006 / 20100604 BX26E /...
  • Page 12 This stove is manufactured with cast iron components. IT DOES NOT HAVE WELDED SEAMS. Periodic “tune up” may be required by refilling and/or replacing the cement/joint mortar along the seams where the cast iron components meet. Page 12 / BX26E VGZ-006 / 20100604...
  • Page 13 ORDERINg PARTS - bX26E bOXwOOD STOvE When ordering missing or replacement parts, always give the Model Number of the stove, Part Number, and Part Description. Use the illustration and parts list provided to identify parts. Part No. Description qty. Leg ............... 4 Bottom ............