All Zone Options; Zone Type - Texecom Premier 412 Installation Manual

Security control panels with integrated communicator
Hide thumbs Also See for Premier 412:
Table of Contents

Advertisement

Programming the Control Panel
From
Previous Page
Zone 00 Att. 3
Enter Zone No.??
15
1
2
3
Alarm
Service
N
Zone 00 Areas
Enter Zone No.??
16
1
2
3
Alarm
Service
N
Zone Name
17
Zone 01 Text
N

All Zone Options

This menu option allows you to program the Zone Type,
Zone Wiring, Zone Attributes 1, Zone Attributes 2, Zone
Attributes 3 and Partitions & Bypass Groups all in one
sequence.

Zone Type

How the alarm system responds, when a zone is violated
depends on the zone type. The following zone types are
available:
"" Null
A zone that is not monitored by the system, unused zones
should be programmed as Null zones.
"! Delay 1
This zone type is normally used for entry/exit detection. The
zone can be violated during the exit delay without causing
an alarm. Once the system/partition is armed, activation of
the zone will start the Entry Delay 1 timer for the selected
partition. The user must disarm the system before the entry
timer elapses or the system will generate an alarm.
"# Delay 2
Operates as Delay 1, but uses Entry Delay 2 timer for the
selected partition.
24
Zone Attributes 3
Enter Zone Number
??
.
Zones
4
5
6
7
8
Armed
Ready
Zone Partitions & Bypass Groups
Enter Zone Number
??
.
Zones
4
5
6
7
8
Armed
Ready
Zone Text
U
Use
to select Zone.
n
Press
to edit text.
!"/
!!
Premier 412/816/832 Installation Manual
Zone 01 Att. 3
Zone Attributes 3
> 1******* <
1
2
3
Zones
1
2
3
4
5
6
7
8
Armed
Alarm
4
Service
Ready
5
6
1 8
Use keys
-
to
7
select/deselect Attributes.
8
y
a
Then press
or
Zone Attributes 3 (Key Switch)
3
4
6
Zone 01 Areaas
Zone Partitions & Bypass Groups
> 1******* <
1
2
3
Zones
1
2
3
4
5
6
7
8
Alarm
Armed
4
Service
Ready
5
6
1 8
Use keys
-
to
7
select/deselect Attributes.
8
y
a
Then press
or
Zone Name
Text Editing Keys
^one 01 Text
1
2
3
Use keys to enter/edit text.
4
y
Then press
to accept.
5
6
7
8
9
0
U
R
"$ Interior Follower
This zone type is normally used for interior detection
devices, such as passive infrared sensors. The zone will not
cause an alarm if violated during the entry delay. However, if
the zone is violated before the entry delay has started, it will
generate an instant alarm.
"% Interior Instant
This zone type is normally used for interior detection where
an instant response is required. The zone will cause an
instant alarm if it is violated when the system/partition is
armed.
"& Perimeter Instant
This zone type is normally used for perimeter protection,
windows, patio doors etc. The zone will cause an instant
alarm if it is violated when the system/partition is armed.
"' Fire
This zone type is normally used for monitoring smoke
detectors. The zone will cause a unique alarm with
distinctive 'fire' tone if it is violated when the system/partition
is armed or disarmed. In addition, the bell output will be
pulsed rather than sounding continuously as with a normal
alarm.
If the "Double Knock" attribute is enabled on a Fire zone, the
zone will behave as a verified fire zone. On the first activation
Change to Delay 1 on Stay Arm
Change to Follower on Stay Arm
Zone Warning
Auto Reinstate if Force Armed
Disable Key Switch if Away Armed
Disable Exit Faults
Truncate Exit Delay
Forced Walk Test
Key Switch is Instant Arming
Key Switch will Stay Arm/Disarm
Disable Auto Arm
Enabled for Partition 1
Enabled for Partition 2
Enabled for Partition 3
Enabled for Partition 4
Enabled for Bypass Group 1
Enabled for Bypass Group 2
Enabled for Bypass Group 3
Enabled for Bypass Group 4
. , ? ! 1 @ " - &
a b c 2 A B C
d e f 3 D E F
g h I 4 G H I
j k l 5 J K L
m n o 7 M N O
p q r s 7 P Q R S
t u v 8 T U V
w x y z 9 W X Y Z
Space 0 , # *
Move Left/Right
Backspace (delete)
INS159-7