Texecom Premier 48-W Quick Start Manual
Hide thumbs Also See for Premier 48-W:

Advertisement

Quick Start Guide

Premier 48-W
INS531

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Premier 48-W and is the answer not in the manual?

Questions and answers

Summary of Contents for Texecom Premier 48-W

  • Page 1: Quick Start Guide

    Quick Start Guide Premier 48-W INS531...
  • Page 2: Table Of Contents

    Premier 48-W Quick Start Guide Contents Contents ..............2 1. Introduction ............3 System Design Considerations ..........3 2. System Overview..........4 System Architecture ..............4 Control Panel Features ............4 3. Installation ............5 Installation Sequence ............. 5 Control Panel ................5 Control Panel Layout ..............
  • Page 3: Introduction

    Once all of the devices have been learnt, they will need placing in their desired location, this should be done by installing devices closest to the Premier 48-W first and then working outwards so that the last devices installed are those furthest away from the control panel.
  • Page 4: System Overview

    Premier 48-W Quick Start Guide 2. System Overview System Architecture 0 to 48 Zones 4 K eypads 2 O utput Modules 3 E xpanders 32 W ireles s Devic e s lots 16 Programmable 100mA Outputs 8 Zone Inputs 2 Zone...
  • Page 5: Installation

    Premier 48-W Quick Start Guide 3. Installation This manual is a quick start guide and details how to learn Control Panel Ricochet™ devices to the system, full programming details for all other system features and functions can be found in the Premier 48...
  • Page 6: Control Panel Layout

    Premier 48-W Quick Start Guide Control Panel Layout OP TIONS E ngineer R E M C LA S S 2 DANG E R HIG H V O LTAG E R E P LA C E ME NT TF M-018 FUS E 230V;...
  • Page 7: Control Panel Pcb Layout

    Premier 48-W Quick Start Guide Control Panel PCB Layout Tamper Dis able OP T IO NS E ngineer R E M 1: AC Input 8: PTC Protection Fuses Connected to the 16.5V transformer. The following fuses are provided: DO NOT CONNECT THE MAINS SUPPLY TO THE AC INPUT •...
  • Page 8 32: Engineers Keypad Use to select the receiver functionality. A portable Engineers keypad can be plugged on here to allow easier Switch 1 OFF =not used on Premier 48-W. access for programming and testing. Switch 2 OFF = Premier 48-W RICOCHET™Mode ...
  • Page 9: Learning Devices

    Premier 48-W Quick Start Guide 4. Learning Devices Option Switch Settings    Option switches 1, 2 & 4 should be OFF.   Configuring Radio devices / Up to 32 wireless devices of any combination can be learnt on to the system.
  • Page 10: Expander Engineer Keypad Functions

    Premier 48-W Quick Start Guide 5. Expander Engineer Keypad Functions The Engineers Keypad can be connected directly to the expander, Change Premier SmartKey™ attributes and has the following features & functions. Premier SmartKey™ attribute changes should be saved by either ...
  • Page 11: Update Devices

    Premier 48-W Quick Start Guide Walktest Mode Update Devices Used to initiate & stop Walktest Mode Used to immediately update devices (NOT Premier SmartKey™) attributes when changed in the Device List menu.      /   ...
  • Page 12: Walktest Mode

     = Commission Mode has been lost on the system.    = the Wireless Network. (not the Premier Network)  = RICOCHET™ Panel Firmware  = Not shown on Premier 48-W     Bottom line indicates  / ...
  • Page 13: Attributes & Operation Modes

    Premier 48-W Quick Start Guide 6. Attributes & Operation Modes Polling Premier SmartKey™ Polling occurs between the devices and the receiver at a pre- LED Indications determined interval of 15 minutes. This helps to conserve battery life. Poll intervals are set to 4 minutes when the system is in Premier SmartKey™...
  • Page 14: Commission Mode

    Premier 48-W Quick Start Guide Alarm Status LED’s Device Commission Mode The alarm status LED’s when enabled will indicate the system status At any time, when a tamper is generated on a device it will enter to the user, however considerations need to be given when the user commission mode, the devices will do this regardless of the state of is allocated to more than one area.
  • Page 15: Other Hardwired Devices

    Zone Expanders red lead on the left most pin of the digi modem connector. The Premier 48-W can use hardwired expanders in addition to the onboard wireless. When using the Premier 8XP or the PSU200XP the address of the first additional expander used should be set to 2 or higher.
  • Page 16: Specifications

    Premier 48-W Quick Start Guide 8. Specifications Control Panel Power supply Mains Supply Voltage: 230VAC (±10%) Maximum Total Current Rating 16.5VAC, 20VA transformer: 1.0ADC Ripple <5% Electrical Current Consumption Quiescent <150mA Alarm (with speaker) <175mA Fuses Mains (1.0ADC) 125mA, 250V, 20mm Battery 1.6A, 250V PTC...
  • Page 17: Standards

    Premier 48-W is covered by a two-year warranty against defects in material or workmanship. As the Premier 48-W expander is not a complete alarm system but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Premier 48-W failed to function correctly. Due to our policy of continuous improvement Texecom reserve the right to change specification without prior notice.
  • Page 18: Notes

    Premier 48-W Quick Start Guide Notes INS531...
  • Page 19: Notes

    Premier 48-W Quick Start Guide Notes INS531...
  • Page 20 Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW, England. Technical Support: UK Customers Tel: 08456 300 600 (Calls charged at local rate from a BT landline. Calls from other networks may vary.) International Customers Tel: +44 1278 686197 Email: techsupport@texe.com...

Table of Contents